Assessment of the reproducibility and accuracy of the Visia ® Complexion Analysis Camera System for objective skin analysis of facial wrinkles and skin age

Helga Henseler

GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW · 2023-10-02 · 12 (Doc07) · Doc07-Doc07

DOI: 10.3205/iprs000177 ↗

At a glance

Journal article in GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW, published on 2023-10-02. Written by Helga Henseler. Institution: Klinik am Rhein, Klinik für Plastische und Ästhetische Chirurgie, Düsseldorf, Germany. Cited 6 times so far (Crossref). The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

This study aimed to investigate the reproducibility and accuracy of the Visia® Complexion Analysis Camera System by Canfield Scientific for objective skin analysis.

Methods

Nineteen participants underwent facial capture with the Visia® camera following a standardised protocol. During the first session, the participants sat down and positioned their faces in a capture rig, closed their eyes and had their faces captured from the left, front and right sides, with threefold repetition of the captures from the front side. After 4 weeks, the participants underwent recapture in a similar manner. Based on the frontal views, data for two measurement methods of the Visia® camera system, the absolute scores and the percentiles, were obtained with regard to the skin criterion wrinkles via automated software calculation. Means and standard deviations were evaluated. Based on the side views, the data for the Truskin Ages® were calculated by the Visia® camera system and compared with the calendrical ages, which served as the gold standard for comparison.

Results

In the assessment of the reproducibility of the data of the capture system the standard deviation from the frontal captures among all participants was about 3% when the absolute scores of the wrinkles were compared with each other; specifically, the average deviation was 3.36% during the first capture session and 3.4% during the second capture session. Meanwhile, the standard deviation of the measurements was about 9% when the percentiles were compared; specifically, the average deviation was 8.2% during the first capture session and 10.7% during the second capture session. In the assessment of the accuracy the correlation between the calendrical age and the calculated Truskin Age® for both facial sides was very high at a correlation coefficient rho value of >0.8 (right side: r=0.896; left side: r=0.827) and statistically significant at a p-value of

Subjects

Author keywords

Visia® Complexion Analysis Camera Systemaccuracyfacial captureobjective measurementsprecisionreproducibilityvalidationwrinkles

Authors and institutions

  • Klinik am Rhein, Klinik für Plastische und Ästhetische Chirurgie, Düsseldorf, Germany.

Cite

APA

Henseler, H. (2023). Assessment of the reproducibility and accuracy of the Visia ® Complexion Analysis Camera System for objective skin analysis of facial wrinkles and skin age. GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW, 12(Doc07), Doc07-Doc07. https://doi.org/10.3205/iprs000177

Vancouver

Henseler H. Assessment of the reproducibility and accuracy of the Visia ® Complexion Analysis Camera System for objective skin analysis of facial wrinkles and skin age. GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW. 2023;12(Doc07):Doc07-Doc07. doi:10.3205/iprs000177

BibTeX
@article{Henseler2023,
  author = {Henseler, Helga},
  title = {Assessment of the reproducibility and accuracy of the Visia ® Complexion Analysis Camera System for objective skin analysis of facial wrinkles and skin age},
  journal = {GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW},
  year = {2023},
  volume = {12},
  number = {Doc07},
  pages = {Doc07--Doc07},
  doi = {10.3205/iprs000177}
}
Start for free →