Evaluation of the decontamination efficacy of a portable air cleaner using 275-nm UVC-LED radiation against airborne Coronavirus and Influenza virus
GMS Hygiene and Infection Control · 15.08.2025 · 20 (Doc44) · Doc44
DOI: 10.3205/dgkh000573 ↗Kurz gefasst
Fachartikel in der Zeitschrift GMS Hygiene and Infection Control, erschienen am 15.08.2025. Verfasst von Janina Reissner und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Animal Hygiene and Environmental Health, Veterinary Centre for Resistance Research - TZR, School of Veterinary Medicine, Freie Universit…. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The COVID-19 pandemic has highlighted the risk of airborne transmission of viruses, especially in public indoor spaces or healthcare settings. Effective indoor air purification systems are necessary to limit the spread of these pathogens, and the deployment of portable air cleaners (PACs) has increased rapidly since then. Germicidal ultraviolet (UV) radiation technologies have recently supplemented conventional air filtration technologies. Thus, the purpose of this study was to evaluate the air decontamination efficacy of a PAC using a 275-nm UVC-LED unit and fibrous-media air filters.
Method
Two different filters were used in the study: a High-Efficiency Particulate Air (HEPA) filter and an Efficient Particulate Air (EPA) filter. The PAC was operated in an experimental aerosol chamber with an airflow rate of 200 m³/hour for 10 or 20 minutes. Subsequently, the concentration of infectious viruses and particles in the air was measured. Decontamination efficacy was compared between UVC-LED radiation, filtration, and a combination thereof against Feline Coronavirus (FCoV) and influenza A virus (H3N2) aerosols.
Results
Infectious virus reductions were comparable between the UVC and filter measurements. A decrease of 94% in FCoV concentration was observed after 10 minutes of device runtime, increasing to 99.8% after 20 minutes compared to control measurements. H3N2 showed greater susceptibility, with a reduction of 99.7% achieved after 10 minutes. Interestingly, a synergistic effect was observed with significantly lower virus concentrations when both technologies were combined.
Conclusion
These findings highlight the potential of PACs equipped with emerging UVC-LED technologies as effective tools for indoor air decontamination. The deployment of PACs equipped with UVC radiation and filtration could be a promising alternative or supplement to ventilation systems, especially in healthcare settings and other public spaces.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Animal Hygiene and Environmental Health, Veterinary Centre for Resistance Research - TZR, School of Veterinary Medicine, Freie Universität Berlin, Berlin, Germany.
- Chemical and Veterinary Investigation Office Freiburg, Freiburg, Germany.
- Animal Health and Animal Welfare, Faculty of Agricultural and Environmental Sciences, University of Rostock, Rostock, Germany.
- Federal Office of Consumer Protection and Food Safety, Department Veterinary Drugs, Berlin, Germany.
- Hermann-Rietschel-Institut, Technische Universität Berlin, Berlin, Germany.
Zitieren
APA
Reissner, J., Reichelt, B., Siller, P., Brockmann, G., Kriegel, M., Roesler, U., & Friese, A. (2025). Evaluation of the decontamination efficacy of a portable air cleaner using 275-nm UVC-LED radiation against airborne Coronavirus and Influenza virus. GMS Hygiene and Infection Control, 20(Doc44), Doc44. https://doi.org/10.3205/dgkh000573
Vancouver
Reissner J, Reichelt B, Siller P, Brockmann G, Kriegel M, Roesler U, et al. Evaluation of the decontamination efficacy of a portable air cleaner using 275-nm UVC-LED radiation against airborne Coronavirus and Influenza virus. GMS Hygiene and Infection Control. 2025;20(Doc44):Doc44. doi:10.3205/dgkh000573
BibTeX
@article{Reissner2025,
author = {Reissner, Janina and Reichelt, Benjamin and Siller, Paul and Brockmann, Gerrid and Kriegel, Martin and Roesler, Uwe and Friese, Anika},
title = {Evaluation of the decontamination efficacy of a portable air cleaner using 275-nm UVC-LED radiation against airborne Coronavirus and Influenza virus},
journal = {GMS Hygiene and Infection Control},
year = {2025},
volume = {20},
number = {Doc44},
pages = {Doc44},
doi = {10.3205/dgkh000573}
}