Comparative study of inactivation efficacy of far‐ UVC (222 nm) and germicidal UVC (254 nm) radiation against virus‐laden aerosols of artificial human saliva
Photochemistry and Photobiology · 2025-11 · 101 (6) · 1415-1428
DOI: 10.1111/php.14062 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Photochemistry and Photobiology, online erschienen am 19.01.2025. Verfasst von Monika und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India. Hauptthemen laut MEDLINE: Ultraviolet Rays, Saliva, Disinfection, Virus Inactivation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Prime Minister's Research Fellowship (PMRF), Industrial Research & Consultancy Centre (IRCC), Indian Institute of Technology Bombay, Biotechnology Industry Research Assistance Council (BIRAC).
Abstract (Originalsprache)
Virus‐laden aerosols play a substantial role in the spread of numerous infectious diseases, particularly in enclosed indoor settings. Ultraviolet‐C (UVC) disinfection is known to be a highly efficient method for disinfecting pathogenic airborne viruses. Recent recommendations suggest using far‐UVC radiation (222 nm) emitted by KrCl* (krypton‐chloride) excimer lamps to disinfect high‐risk public spaces due to lower exposure risks than low‐pressure (LP) mercury lamps (254 nm). This study experimentally explored the comparative effectiveness of far‐UVC (222 nm) and germicidal UVC (254 nm) in inactivating virus‐laden aerosols of different protective vector media in an air disinfection chamber. The UVC inactivation performances of individual filtered KrCl* excimer lamp and LP mercury lamp were determined for inactivating the bacteriophages, MS2 (icosahedral and non‐enveloped ssRNA virus) and Phi6 (spherical and enveloped dsRNA virus) aerosolized from artificial human saliva or sodium chloride and magnesium sulfate (SM) buffer as a vector media. Disinfection efficacy of filtered KrCl* excimer lamp (222 nm) and LP mercury lamp (254 nm) were evaluated for highly concentrated viral aerosols, which replicate those exhaled from infected individuals and remain suspended in air or deposited on surfaces as fomites. Our results show that using individual filtered KrCl* excimer lamp (222 nm) and LP mercury lamp (254 nm) could greatly accelerate the inactivation of the viral bioaerosols formed from artificial human saliva and SM buffer. In the case of 222 nm exposure, Phi6 exhibited significantly more susceptibility in artificial human saliva than in SM buffer whereas MS2 showed comparable vulnerability in both artificial human saliva and SM buffer. However, in the case of 254 nm exposure, both Phi6 and MS2 demonstrated significantly greater susceptibility in artificial human saliva than in SM buffer. This study offers valuable insights and improves our understanding of the influence of different vector media on UVC disinfection of exhaled virus‐laden aerosols in indoor environments. These findings can guide the deployment of UVC devices which could greatly contribute to mitigating the transmission of exhaled bioaerosols in public settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
- Koita Centre for Digital Health (KCDH), Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
ORCID-Profile: Ambarish Kunwar
Förderung
- Prime Minister's Research Fellowship (PMRF)
- Industrial Research & Consultancy Centre (IRCC), Indian Institute of Technology Bombay
- Biotechnology Industry Research Assistance Council (BIRAC)
- TIH Foundation for IoT and IoE (TIH-IoT)
Zitieren
APA
Monika, Damle, E. A., Kondabagil, K., & Kunwar, A. (2025). Comparative study of inactivation efficacy of far‐ UVC (222 nm) and germicidal UVC (254 nm) radiation against virus‐laden aerosols of artificial human saliva. Photochemistry and Photobiology, 101(6), 1415-1428. https://doi.org/10.1111/php.14062
Vancouver
Monika, Damle EA, Kondabagil K, Kunwar A. Comparative study of inactivation efficacy of far‐ UVC (222 nm) and germicidal UVC (254 nm) radiation against virus‐laden aerosols of artificial human saliva. Photochemistry and Photobiology. 2025;101(6):1415-1428. doi:10.1111/php.14062
BibTeX
@article{Monika2025,
author = {Monika and Damle, Eeshan Ajay and Kondabagil, Kiran and Kunwar, Ambarish},
title = {Comparative study of inactivation efficacy of far‐ UVC (222 nm) and germicidal UVC (254 nm) radiation against virus‐laden aerosols of artificial human saliva},
journal = {Photochemistry and Photobiology},
year = {2025},
volume = {101},
number = {6},
pages = {1415--1428},
doi = {10.1111/php.14062}
}
EUVIMED