EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY-SA 4.0

Integrated Indoor Air Quality Protocol for an Additive Manufacturing Workshop: Case Study of FabLab President University

Azka Leona Mayriza, Yosef Barita Sar Manik

JURNAL KESEHATAN LINGKUNGAN: Jurnal dan Aplikasi Teknik Kesehatan Lingkungan · 31.07.2026 · 23 (2) · 267-280

DOI: 10.31964/jkl.v23i2.1138 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift JURNAL KESEHATAN LINGKUNGAN: Jurnal dan Aplikasi Teknik Kesehatan Lingkungan, online erschienen am 31.07.2026. Verfasst von Azka Leona Mayriza und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The indoor air quality (IAQ) issues in 3D Printing Workshop arise from high equipment usage, material handling, and continuous student presence. 3D printing process generates pollutants that may threaten health and safety. Due to Indonesia's currently lacks a specific national standard for IAQ specifically in 3D Printing Workshop, creating a regulatory gap for these educational facilities. This study conducted a regulatory inventory to identify applicable standards for IAQ in the 3D Printing Workshop at President University. Two national regulations were included as part of this inventory: Permenkes No. 2 Tahun 2023 and Permenaker No. 5 Tahun 2018 as primary sources. Regulations were selected based on legal authority, parameter coverage, relevance to workshop activities, and strictness of threshold limits to support a comprehensive and health-protective assessment approach. Eight key IAQ parameters were identified: temperature, relative humidity, Air Velocity, noise level, PM10, PM2.5, total suspended particles (TSP), and volatile organic compound (VOC). These reflect thermal comfort, contamination, physical hazards, and chemical pollutants from 3D printing processes and human occupancy. The study proposes a systematic IAQ parameter framework integrating standard measurement techniques as a conceptual reference for environmental monitoring, regulatory compliance, occupational health and safety (OSH) practices, and higher education accreditation requirements.

Zitieren

APA

Mayriza, A. L., & Manik, Y. B. S. (2026). Integrated Indoor Air Quality Protocol for an Additive Manufacturing Workshop: Case Study of FabLab President University. JURNAL KESEHATAN LINGKUNGAN: Jurnal dan Aplikasi Teknik Kesehatan Lingkungan, 23(2), 267-280. https://doi.org/10.31964/jkl.v23i2.1138

Vancouver

Mayriza AL, Manik YBS. Integrated Indoor Air Quality Protocol for an Additive Manufacturing Workshop: Case Study of FabLab President University. JURNAL KESEHATAN LINGKUNGAN: Jurnal dan Aplikasi Teknik Kesehatan Lingkungan. 2026;23(2):267-280. doi:10.31964/jkl.v23i2.1138

BibTeX
@article{Mayriza2026,
  author = {Mayriza, Azka Leona and Manik, Yosef Barita Sar},
  title = {Integrated Indoor Air Quality Protocol for an Additive Manufacturing Workshop: Case Study of FabLab President University},
  journal = {JURNAL KESEHATAN LINGKUNGAN: Jurnal dan Aplikasi Teknik Kesehatan Lingkungan},
  year = {2026},
  volume = {23},
  number = {2},
  pages = {267--280},
  doi = {10.31964/jkl.v23i2.1138}
}
Kostenlos starten →