EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Indoor Air Quality and Bioaerosols in Spanish University Classrooms

Esther Fuentes-Ferragud iD, Antonio López, Juan Miguel Piera, Vicent Yusà, Salvador Garrigues iD, Miguel de la Guardia, F Xavier López Labrador iD, Marisa Camaró, María Ibáñez iD, Clara Coscollà

Toxics · 20.03.2024 · 12 (3) · 227

DOI: 10.3390/toxics12030227 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Toxics, online erschienen am 20.03.2024. Verfasst von Esther Fuentes-Ferragud und 9 weiteren Autor:innen. Beteiligte Einrichtung: Foundation for the Promotion of Health and Biomedical Research in the Valencia Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020 Valencia, …. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, AIRCOV project “Detection of SARS-CoV-2 in the indoor air of Health and Educational Centers”, European Regional Development Funds (ERDF) Operational Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A comprehensive study assessed indoor air quality parameters, focusing on relevant air pollutants such as particulate matter (PM10 and PM2.5), gaseous compounds (CO, CO2, formaldehyde, NO2) and volatile/semi-volatile organic chemicals, as well as respiratory viruses (including SARS-CoV-2), fungi and bacteria in Spanish university classrooms. Non-target screening strategies evaluated the presence of organic pollutants inside and outside the classrooms. Saliva samples from teachers and students were collected to explore correlations between respiratory viruses in the air and biological samples. Indoor results revealed the punctual exceedance of recommended guidelines for CO2, formaldehyde (HCHO), volatile organic compounds (TVOCs) and PM in the least naturally ventilated classrooms. Significant differences occurred between the classes, with the least ventilated one showing higher average concentrations of CO2, HCHO, NO2, PM10 and PM2.5. A respiratory virus (rhinovirus/enterovirus) was detected in the medium naturally ventilated classroom, although saliva samples tested negative. Suspect screening tentatively identified 65 substances indoors and over 200 outdoors, with approximately half reporting a high toxicological risk based on the Cramer rules. The study provides a comprehensive overview of indoor air quality, respiratory viruses and organic pollutants in university classrooms, highlighting the variations and potential health risks associated with ventilation differences.

Schlagwörter

Stichwörter der Autor:innen

classroomsindoor air qualitynon-target screeningrespiratory virusessalivauniversity

Autor:innen und Institutionen

  • Foundation for the Promotion of Health and Biomedical Research in the Valencia Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020 Valencia, Spain.
  • Environmental and Public Health Analytical Chemistry, Research Institute for Pesticides and Water, University Jaume I, S/N, Avenida Sos Baynat, 12071 Castelló de la Plana, Spain.
  • Public Health Laboratory of Valencia, 21, Avenida Catalunya, 46020 Valencia, Spain.
  • Analytical Chemistry Department, University of Valencia, Edifici Jeroni Muñoz, Dr. Moliner 50, 46100 Burjassot, Spain.
  • Microbiology Department, University of Valencia Medical School, Av. de Blasco Ibáñez, 13, 46010 Valencia, Spain.
  • CIBERESP, Institute of Health Carlos III, Sinsesio Delgado Street, 4, 28029 Madrid, Spain.

ORCID-Profile: Esther Fuentes-Ferragud, Salvador Garrigues, F Xavier López Labrador, María Ibáñez

Förderung

  • European Commission
  • AIRCOV project “Detection of SARS-CoV-2 in the indoor air of Health and Educational Centers”
  • European Regional Development Funds (ERDF) Operational Programme
  • European Commission under the European Regional Development Fund (ERDF) Operational Programme of the Valencia Region

Zitieren

APA

Fuentes-Ferragud, E., López, A., Piera, J. M., Yusà, V., Garrigues, S., de la Guardia, M., López Labrador, F. X., Camaró, M., Ibáñez, M., & Coscollà, C. (2024). Indoor Air Quality and Bioaerosols in Spanish University Classrooms. Toxics, 12(3), 227. https://doi.org/10.3390/toxics12030227

Vancouver

Fuentes-Ferragud E, López A, Piera JM, Yusà V, Garrigues S, de la Guardia M, et al. Indoor Air Quality and Bioaerosols in Spanish University Classrooms. Toxics. 2024;12(3):227. doi:10.3390/toxics12030227

BibTeX
@article{FuentesFerragud2024,
  author = {Fuentes-Ferragud, Esther and López, Antonio and Piera, Juan Miguel and Yusà, Vicent and Garrigues, Salvador and de la Guardia, Miguel and López Labrador, F Xavier and Camaró, Marisa and Ibáñez, María and Coscollà, Clara},
  title = {Indoor Air Quality and Bioaerosols in Spanish University Classrooms},
  journal = {Toxics},
  year = {2024},
  volume = {12},
  number = {3},
  pages = {227},
  doi = {10.3390/toxics12030227}
}
Kostenlos starten →