EUVIMEDEUVIMED entdecken
Open Access

DANTE-CAIPI Accelerated Contrast-Enhanced 3D T1: Deep Learning–Based Image Quality Improvement for Vessel Wall MRI

Mona Kharaji, Gador Canton iD, Yin Guo iD, Mohamad Hosaam Mosi, Zechen Zhou, Niranjan Balu iD, Mahmud Mossa-Basha iD

American Journal of Neuroradiology · 2025

DOI: 10.3174/ajnr.a8424 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Neuroradiology, 2025. Verfasst von Mona Kharaji und 6 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Radiology (M.K., G.C., M.H.M., N.B., M.M.-B.), University of Washington School of Medicine, Seattle, Washington. Hauptthemen laut MEDLINE: Deep Learning, Imaging, Three-Dimensional, Contrast Media. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, National Institute of Neurological Disorders and Stroke.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: Accelerated and blood-suppressed postcontrast 3D intracranial vessel wall MRI (IVW) enables high-resolution rapid scanning but is associated with low SNR. We hypothesized that a deep-learning (DL) denoising algorithm applied to accelerated, blood-suppressed postcontrast IVW can yield high-quality images with reduced artifacts and higher SNR in shorter scan times. MATERIALS AND METHODS: Sixty-four consecutive patients underwent IVW, including conventional postcontrast 3D T1-sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) and delay alternating with nutation for tailored excitation (DANTE) blood-suppressed and CAIPIRINHIA-accelerated (CAIPI) 3D T1-weighted TSE postcontrast sequences (DANTE-CAIPI-SPACE). DANTE-CAIPI-SPACE acquisitions were then denoised by using an unrolled deep convolutional network (DANTE-CAIPI-SPACE+DL). SPACE, DANTE-CAIPI-SPACE, and DANTE-CAIPI-SPACE+DL images were compared for overall image quality, SNR, severity of artifacts, arterial and venous suppression, and lesion assessment by using 4-point or 5-point Likert scales. Quantitative evaluation of SNR and contrast-to-noise ratio (CNR) was performed. RESULTS: DANTE-CAIPI-SPACE+DL showed significantly reduced arterial (1 [1-1.75] versus 3 [3-4], P < .001) and venous flow artifacts (1 [1-2] versus 3 [3-4], P < .001) compared with SPACE. There was no significant difference between DANTE-CAIPI-SPACE+DL and SPACE in terms of image quality, SNR, artifact ratings, and lesion assessment. For SNR ratings, DANTE-CAIPI-SPACE+DL was significantly better compared with DANTE-CAIPI-SPACE (2 [1-2], versus 3 [2-3], P < .001). No statistically significant differences were found between DANTE-CAIPI-SPACE and DANTE-CAIPI-SPACE+DL for image quality, artifact, arterial blood and venous blood flow artifacts, and lesion assessment. Quantitative vessel wall SNR and CNR median values were significantly higher for DANTE-CAIPI-SPACE+DL (SNR: 9.71, CNR: 4.24) compared with DANTE-CAIPI-SPACE (SNR: 5.50, CNR: 2.64) (P < .001 for each), but there was no significant difference between SPACE (SNR: 10.82, CNR: 5.21) and DANTE-CAIPI-SPACE+DL. CONCLUSIONS: DL denoised postcontrast T1-weighted DANTE-CAIPI-SPACE accelerated and blood-suppressed IVW showed improved flow suppression with a shorter scan time and equivalent qualitative and quantitative SNR measures relative to conventional postcontrast IVW. It also improved SNR metrics relative to postcontrast DANTE-CAIPI-SPACE IVW. Implementing DL denoised DANTE-CAIPI-SPACE IVW has the potential to shorten protocol time while maintaining or improving the image quality of IVW.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningImaging, Three-DimensionalContrast MediaHumansMaleFemaleMiddle AgedAgedAdultQuality ImprovementMagnetic Resonance ImagingSignal-To-Noise RatioArtifactsImage Enhancement

Substanzen

Contrast Media

Autor:innen und Institutionen

  • From the Department of Radiology (M.K., G.C., M.H.M., N.B., M.M.-B.), University of Washington School of Medicine, Seattle, Washington.
  • Department of Bioengineering (Y.G.), University of Washington, Seattle, Washington.
  • Subtle Medical Inc (Z.Z.), Menlo Park, California.
  • From the Department of Radiology (M.K., G.C., M.H.M., N.B., M.M.-B.), University of Washington School of Medicine, Seattle, Washington mmossab@uw.edu.

ORCID-Profile: Gador Canton, Yin Guo, Niranjan Balu, Mahmud Mossa-Basha

Förderung

  • NINDS NIH HHS
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Kharaji, M., Canton, G., Guo, Y., Mosi, M. H., Zhou, Z., Balu, N., & Mossa-Basha, M. (2025). DANTE-CAIPI Accelerated Contrast-Enhanced 3D T1: Deep Learning–Based Image Quality Improvement for Vessel Wall MRI. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a8424

Vancouver

Kharaji M, Canton G, Guo Y, Mosi MH, Zhou Z, Balu N, et al. DANTE-CAIPI Accelerated Contrast-Enhanced 3D T1: Deep Learning–Based Image Quality Improvement for Vessel Wall MRI. American Journal of Neuroradiology. 2025. doi:10.3174/ajnr.a8424

BibTeX
@article{Kharaji2025,
  author = {Kharaji, Mona and Canton, Gador and Guo, Yin and Mosi, Mohamad Hosaam and Zhou, Zechen and Balu, Niranjan and Mossa-Basha, Mahmud},
  title = {DANTE-CAIPI Accelerated Contrast-Enhanced 3D T1: Deep Learning–Based Image Quality Improvement for Vessel Wall MRI},
  journal = {American Journal of Neuroradiology},
  year = {2025},
  doi = {10.3174/ajnr.a8424}
}
Kostenlos starten →