EUVIMEDExplore EUVIMED
Open access · CC BY-NC-ND 4.0

Paper template–based intraoperative rod bending for percutaneous stabilization of thoracic extension-distraction fracture: illustrative case

Haiyue Jin iD, Alexander M Lopez, Andrew C Vivas, Michael Y Oh, Nitin N Bhatia iD, Yu-Po Lee, Don Y Park iD, Sohaib Z Hashmi, Hao-Hua Wu, Emily S Mills, Hansen Bow

Journal of Neurosurgery: Case Lessons · 2026-07-13 · 12 (2)

DOI: 10.3171/case26257 ↗

At a glance

Journal article in Journal of Neurosurgery: Case Lessons, published on 2026-07-13. Written by Haiyue Jin and 10 co-authors. Institution: Department of Neurosurgery, University of California, Irvine, Orange. 32 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliographic detailsCiteRelated studies

Abstract (original language)

BACKGROUND Distraction fractures are unstable spinal injuries characterized by a horizontal fracture line through the vertebra, often occurring following deceleration mechanisms. Surgical management typically involves fixation and fusion to restore sagittal alignment. Minimally invasive approaches, including percutaneous pedicle screw fixation, have demonstrated reduced operative morbidity while achieving deformity correction comparable to that of open techniques. However, accurate rod contouring in percutaneous procedures remains technically challenging. OBSERVATIONS A 61-year-old male presented with a three-column unstable T7 distraction fracture in the setting of diffuse idiopathic skeletal hyperostosis following a rear-end motor vehicle accident at low to moderate speeds. A T4–10 percutaneous pedicle screw fixation for fracture reduction and stabilization was performed. Preoperative CT images were formatted and printed at a 1:1 scale on a sheet of paper; cut along the fracture line, taped together to reduce the fracture, and photocopied; sterilely bagged; and used intraoperatively to guide rod bending prior to placement. LESSONS Using a 1:1 ratio paper printout of the patient’s preoperative CT scan as an anatomical template, the authors appropriately performed intraoperative rod bending without additional adjustment of rod contour. This method offers a practical, cost-effective solution to improve the precision and efficiency of rod bending in percutaneous spinal fusion. https://thejns.org/doi/10.3171/CASE26257

Subjects

Author keywords

diffuse idiopathic skeletal hyperostosisdistraction fracturelong-segment percutaneous fixationrod bending

Authors and institutions

  • Department of Neurosurgery, University of California, Irvine, Orange.
  • Department of Neurosurgery, University of California, Los Angeles.
  • Department of Orthopaedic Surgery, University of California, Irvine, Orange, California.

ORCID profiles: Haiyue Jin, Nitin N Bhatia, Don Y Park

Cite

APA

Jin, H., Lopez, A. M., Vivas, A. C., Oh, M. Y., Bhatia, N. N., Lee, Y. P., Park, D. Y., Hashmi, S. Z., Wu, H. H., Mills, E. S., & Bow, H. (2026). Paper template–based intraoperative rod bending for percutaneous stabilization of thoracic extension-distraction fracture: illustrative case. Journal of Neurosurgery: Case Lessons, 12(2). https://doi.org/10.3171/case26257

Vancouver

Jin H, Lopez AM, Vivas AC, Oh MY, Bhatia NN, Lee YP, et al. Paper template–based intraoperative rod bending for percutaneous stabilization of thoracic extension-distraction fracture: illustrative case. Journal of Neurosurgery: Case Lessons. 2026;12(2). doi:10.3171/case26257

BibTeX
@article{Jin2026,
  author = {Jin, Haiyue and Lopez, Alexander M and Vivas, Andrew C and Oh, Michael Y and Bhatia, Nitin N and Lee, Yu-Po and Park, Don Y and Hashmi, Sohaib Z and Wu, Hao-Hua and Mills, Emily S and Bow, Hansen},
  title = {Paper template–based intraoperative rod bending for percutaneous stabilization of thoracic extension-distraction fracture: illustrative case},
  journal = {Journal of Neurosurgery: Case Lessons},
  year = {2026},
  volume = {12},
  number = {2},
  doi = {10.3171/case26257}
}
Start for free →