EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Contralateral screw loosening of through-and-through fixation following unilateral sacroiliac joint fusion: illustrative case

Rafael Garcia, Cale Hendricks, David W Polly

Journal of Neurosurgery: Case Lessons · 2026-05-04 · 11 (18)

DOI: 10.3171/case25668 ↗

At a glance

Journal article in Journal of Neurosurgery: Case Lessons, published on 2026-05-04. Written by Rafael Garcia and 2 co-authors. Institution: Department of Orthopedic Surgery, University of Minnesota, Minneapolis, Minnesota. 48 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

BACKGROUND Sacroiliac (SI) joint dysfunction is a frequently underrecognized source of low back pain, implicated in 15%–30% of cases across select populations. Unilateral SI joint fusion remains the most commonly performed technique, utilizing either iliosacral screws or, more recently, through-and-through (TNT) screws. OBSERVATIONS A 65-year-old woman with a history of failed right-sided SI joint fusion underwent revision surgery with bilateral TNT screw fixation due to worsening symptoms. Follow-up imaging confirmed solid right-sided arthrodesis. However, progressive haloing and sclerosis were observed around the left iliac portion of the cephalad screw. LESSONS This case represents the first reported instance of persistent motion and screw haloing using TNT screw fixation when using two spanning screws. These findings highlight a potential limitation of TNT constructs due to load transfer, stress shielding, and asymmetric osseous integration, particularly in patients with a history of prior unilateral SI joint fusion. https://thejns.org/doi/10.3171/CASE25668

Subjects

Author keywords

SIJ fusionTNTfailurefixation screwlucencystress shieldingthrough-and-through

Authors and institutions

  • Department of Orthopedic Surgery, University of Minnesota, Minneapolis, Minnesota.

Cite

APA

Garcia, R., Hendricks, C., & Polly, D. W. (2026). Contralateral screw loosening of through-and-through fixation following unilateral sacroiliac joint fusion: illustrative case. Journal of Neurosurgery: Case Lessons, 11(18). https://doi.org/10.3171/case25668

Vancouver

Garcia R, Hendricks C, Polly DW. Contralateral screw loosening of through-and-through fixation following unilateral sacroiliac joint fusion: illustrative case. Journal of Neurosurgery: Case Lessons. 2026;11(18). doi:10.3171/case25668

BibTeX
@article{Garcia2026,
  author = {Garcia, Rafael and Hendricks, Cale and Polly, David W},
  title = {Contralateral screw loosening of through-and-through fixation following unilateral sacroiliac joint fusion: illustrative case},
  journal = {Journal of Neurosurgery: Case Lessons},
  year = {2026},
  volume = {11},
  number = {18},
  doi = {10.3171/case25668}
}
Start for free →