Unruptured distal anterior cerebral artery branch pseudoaneurysm in the setting of intracranial pressure monitor placement: illustrative case
Journal of Neurosurgery: Case Lessons · 2026-07-13 · 12 (2)
DOI: 10.3171/case251022 ↗At a glance
Journal article in Journal of Neurosurgery: Case Lessons, published on 2026-07-13. Written by Andrew L Waack and 4 co-authors. Institution: Department of Neurosurgery, Froedtert and the Medical College of Wisconsin, Milwaukee, Wisconsin. 16 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
BACKGROUND Intracranial pressure monitors (IPMs) are commonly placed in patients with severe traumatic brain injury to diagnose and guide treatment for intracranial hypertension. Complications of IPM placement include infection, hemorrhage, and malposition. While rare case reports describe ruptured iatrogenic pseudoaneurysms associated with IPM, the incidence and implications of unruptured pseudoaneurysms are poorly understood. OBSERVATIONS A 19-year-old female sustained a severe traumatic brain injury, leading to IPM placement. After a prolonged hospital course, delayed noninvasive imaging to characterize potential cerebrovascular injury raised concern for a carotid-cavernous fistula. Digital subtraction angiography (DSA) ruled out this pathology but revealed an unruptured distal right anterior cerebral artery pseudoaneurysm at the site of the previously placed IPM, which was later successfully treated with endovascular embolization after short-interval repeat DSA. LESSONS While pseudoaneurysm formation is a rarely described complication of ICM placement, they are associated with a high rate of rupture (60%) and, subsequently, high mortality (20%). Thus, a high index of suspicion of potential pseudoaneurysm rupture should be maintained in the setting of a delayed rapid decline in neurological examination or delayed intraparenchymal hemorrhage after IPM placement. Urgent evaluation using CT angiography and/or catheter angiography should be considered in addition to standard noncontrast imaging. https://thejns.org/doi/10.3171/CASE251022
Subjects
Author keywords
Authors and institutions
- Department of Neurosurgery, Froedtert and the Medical College of Wisconsin, Milwaukee, Wisconsin.
ORCID profiles: Andrew L Waack
Cite
APA
Waack, A. L., Feller, C. N., Mackinnon, G. A., Cheok, S. K., & Jareczek, F. J. (2026). Unruptured distal anterior cerebral artery branch pseudoaneurysm in the setting of intracranial pressure monitor placement: illustrative case. Journal of Neurosurgery: Case Lessons, 12(2). https://doi.org/10.3171/case251022
Vancouver
Waack AL, Feller CN, Mackinnon GA, Cheok SK, Jareczek FJ. Unruptured distal anterior cerebral artery branch pseudoaneurysm in the setting of intracranial pressure monitor placement: illustrative case. Journal of Neurosurgery: Case Lessons. 2026;12(2). doi:10.3171/case251022
BibTeX
@article{Waack2026,
author = {Waack, Andrew L and Feller, Christina N and Mackinnon, Gerard A and Cheok, Stephanie K and Jareczek, Francis J},
title = {Unruptured distal anterior cerebral artery branch pseudoaneurysm in the setting of intracranial pressure monitor placement: illustrative case},
journal = {Journal of Neurosurgery: Case Lessons},
year = {2026},
volume = {12},
number = {2},
doi = {10.3171/case251022}
}
EUVIMED