EUVIMEDEUVIMED entdecken
Crossref

Accuracy of routine external ventricular drain placement following a mixed reality–guided twist-drill craniostomy

Sangjun Eom, Tiffany S Ma, Neha Vutakuri, Tianyi Hu, Aden P Haskell-Mendoza, David A W Sykes, Maria Gorlatova, Joshua Jackson

Neurosurgical Focus · 2024-01 · 56 (1) · E11

DOI: 10.3171/2023.10.focus23615 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neurosurgical Focus, 2024-01. Verfasst von Sangjun Eom und 7 weiteren Autor:innen. Beteiligte Einrichtung: Departments of1Electrical and Computer Engineering. Hauptthemen laut MEDLINE: Augmented Reality. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE The traditional freehand placement of an external ventricular drain (EVD) relies on empirical craniometric landmarks to guide the craniostomy and subsequent passage of the EVD catheter. The diameter and trajectory of the craniostomy physically limit the possible trajectories that can be achieved during the passage of the catheter. In this study, the authors implemented a mixed reality–guided craniostomy procedure to evaluate the benefit of an optimally drilled craniostomy to the accurate placement of the catheter. METHODS Optical marker–based tracking using an OptiTrack system was used to register the brain ventricular hologram and drilling guidance for craniostomy using a HoloLens 2 mixed reality headset. A patient-specific 3D-printed skull phantom embedded with intracranial camera sensors was developed to automatically calculate the EVD accuracy for evaluation. User trials consisted of one blind and one mixed reality–assisted craniostomy followed by a routine, unguided EVD catheter placement for each of two different drill bit sizes. RESULTS A total of 49 participants were included in the study (mean age 23.4 years, 59.2% female). The mean distance from the catheter target improved from 18.6 ± 12.5 mm to 12.7 ± 11.3 mm (p = 0.0008) using mixed reality guidance for trials with a large drill bit and from 19.3 ± 12.7 mm to 10.1 ± 8.4 mm with a small drill bit (p < 0.0001). Accuracy using mixed reality was improved using a smaller diameter drill bit compared with a larger bit (p = 0.039). Overall, the majority of the participants were positive about the helpfulness of mixed reality guidance and the overall mixed reality experience. CONCLUSIONS Appropriate indications and use cases for the application of mixed reality guidance to neurosurgical procedures remain an area of active inquiry. While prior studies have demonstrated the benefit of mixed reality–guided catheter placement using predrilled craniostomies, the authors demonstrate that real-time quantitative and visual feedback of a mixed reality–guided craniostomy procedure can independently improve procedural accuracy and represents an important tool for trainee education and eventual clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Augmented RealityHumansFemaleYoung AdultAdultMaleDrainageNeurosurgical ProceduresCerebral VentriclesCatheters

Stichwörter der Autor:innen

HoloLenscraniostomyexternal ventricular drainageimage-guided surgerymixed reality

Autor:innen und Institutionen

  • Departments of1Electrical and Computer Engineering.
  • 2Computer Science.
  • 3Neuroscience, and.
  • 4Neurosurgery, Duke University, Durham, North Carolina.

Förderung

  • National Science Foundation

Zitieren

APA

Eom, S., Ma, T. S., Vutakuri, N., Hu, T., Haskell-Mendoza, A. P., Sykes, D. A. W., Gorlatova, M., & Jackson, J. (2024). Accuracy of routine external ventricular drain placement following a mixed reality–guided twist-drill craniostomy. Neurosurgical Focus, 56(1), E11. https://doi.org/10.3171/2023.10.focus23615

Vancouver

Eom S, Ma TS, Vutakuri N, Hu T, Haskell-Mendoza AP, Sykes DAW, et al. Accuracy of routine external ventricular drain placement following a mixed reality–guided twist-drill craniostomy. Neurosurgical Focus. 2024;56(1):E11. doi:10.3171/2023.10.focus23615

BibTeX
@article{Eom2024,
  author = {Eom, Sangjun and Ma, Tiffany S and Vutakuri, Neha and Hu, Tianyi and Haskell-Mendoza, Aden P and Sykes, David A W and Gorlatova, Maria and Jackson, Joshua},
  title = {Accuracy of routine external ventricular drain placement following a mixed reality–guided twist-drill craniostomy},
  journal = {Neurosurgical Focus},
  year = {2024},
  volume = {56},
  number = {1},
  pages = {E11},
  doi = {10.3171/2023.10.focus23615}
}
Kostenlos starten →