EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of augmented reality visualization approaches in minimally invasive neurosurgery guidance: 2D, tablet, HMD and autostereoscopic displays

Nan Zhang, Wentao Zhao, Tianqi Huang, Ming Feng, Hongen Liao, Hongbin Liu

Medical & Biological Engineering & Computing · 2026

DOI: 10.1007/s11517-025-03460-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Medical & Biological Engineering & Computing, 2026. Verfasst von Nan Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Automation, Chinese Academy of Sciences, Beijing, 100190, China. zhangnan@ia.ac.cn. Hauptthemen laut MEDLINE: Augmented Reality, Minimally Invasive Surgical Procedures, Neurosurgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Youth Program of State Key Laboratory of Multimodal Artificial Intelligence Systems, InnoHK program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Minimally invasive neurosurgery presents specific challenges due to the limited operative space and complex cranial anatomy, requiring highly precise and safe surgical guidance. Augmented Reality (AR) technology offers the potential to improve surgical accuracy and safety by overlaying critical digital information onto real-world surgical environments. In this study, we present a study that aims to compare four AR visualization methods-2D flat display, smart tablet, head-mounted display (HMD), and 3D autostereoscopic display-in guiding minimally invasive neurosurgical procedures, specifically focusing on ventriculocentesis. The effectiveness of the AR methods was evaluated through comprehensive user studies involving 32 participants (including 11 experienced surgeons), with assessment focused on critical performance metrics including accuracy, completion time, usability, and cognitive workload during simulated surgical procedures. Results demonstrated that 3D visualization methods significantly outperformed traditional 2D approaches in terms of puncture accuracy and angular precision. Specifically, surgeons showed a statistically significant improvement in localization accuracy, with mean error reduced from 2.69 mm to 1.67 mm, and angular deviation from 5.62° to 1.54°. In comparing the two 3D visualization systems, the HMD exhibited superior task completion efficiency, while the 3D autostereoscopic display demonstrated higher usability scores and lower perceived workload ratings. Notably, the 3D systems effectively reduced the performance disparity between novice and experienced practitioners, suggesting their potential to accelerate the learning curve for less experienced users. We conclude that AR holds significant potential to enhance performance and decision-making in minimally invasive neurosurgical guidance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Augmented RealityMinimally Invasive Surgical ProceduresNeurosurgical ProceduresSurgery, Computer-AssistedHumansImaging, Three-DimensionalMaleFemaleAdult

Stichwörter der Autor:innen

3D visualization techniquesAugmented realityMinimally invasive neurosurgerySurgical navigationUser study

Autor:innen und Institutionen

  • Institute of Automation, Chinese Academy of Sciences, Beijing, 100190, China. zhangnan@ia.ac.cn.
  • Institute of Automation, Chinese Academy of Sciences, Beijing, 100190, China.
  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
  • Department of Neurosurgery, Peking Union Medical College Hospital, Beijing, 100730, China.
  • Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China.
  • School of Biomedical Engineering and the Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, 200240, China.

Förderung

  • National Natural Science Foundation of China
  • Youth Program of State Key Laboratory of Multimodal Artificial Intelligence Systems
  • InnoHK program

Zitieren

APA

Zhang, N., Zhao, W., Huang, T., Feng, M., Liao, H., & Liu, H. (2026). Comparison of augmented reality visualization approaches in minimally invasive neurosurgery guidance: 2D, tablet, HMD and autostereoscopic displays. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-025-03460-5

Vancouver

Zhang N, Zhao W, Huang T, Feng M, Liao H, Liu H. Comparison of augmented reality visualization approaches in minimally invasive neurosurgery guidance: 2D, tablet, HMD and autostereoscopic displays. Medical & Biological Engineering & Computing. 2026. doi:10.1007/s11517-025-03460-5

BibTeX
@article{Zhang2026,
  author = {Zhang, Nan and Zhao, Wentao and Huang, Tianqi and Feng, Ming and Liao, Hongen and Liu, Hongbin},
  title = {Comparison of augmented reality visualization approaches in minimally invasive neurosurgery guidance: 2D, tablet, HMD and autostereoscopic displays},
  journal = {Medical & Biological Engineering & Computing},
  year = {2026},
  doi = {10.1007/s11517-025-03460-5}
}