Fachartikel in der Zeitschrift Physiotherapy Canada, erschienen am 01.11.2019. Verfasst von Erica Zurawski und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, University of Toronto. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to estimate the interrater reliability of the Modified Ashworth Scale (MAS) using consistent movement speeds guided by a metronome when measuring wrist flexor and ankle plantar flexor spasticity in patients with an upper motor neuron (UMN) lesion. The MAS has been found to have inconsistent interrater reliability for scoring the degree of spasticity.

Method

This quantitative cross-sectional pilot study occurred in the outpatient spasticity clinic of a community rehabilitation hospital. Participants were a convenience sample of 20 patients with UMN lesions receiving botulinum toxin type A injections for focal spasticity. For each of the muscle groups tested, different pairs of evaluators scored spasticity on the MAS at a velocity of 130° per second. Evaluators were physical therapy students trained by an experienced physical therapist in MAS assessment. Weighted κ values were calculated to measure interrater reliability for each muscle group.

Results

The weighted κ values for the wrist flexors and ankle plantar flexors were, respectively, moderate (κ w = 0.54; 95% CI: 0.21, 0.87) and slight (κ w = 0.08; 95% CI: −0.34, 0.50).

Conclusion

Using consistent movement velocity, novice evaluators were able to score spasticity with reasonable interrater reliability when assessing the wrist flexors but not the ankle plantar flexors.

Schlagwörter

Stichwörter der Autor:innen

brain injuriesmultiple sclerosismuscle spasticityreproducibility of resultsstroke

Autor:innen und Institutionen

  • Department of Physical Therapy, University of Toronto.
  • West Park Healthcare Centre, Toronto.

Zitieren

APA

Zurawski, E., Behm, K., Dunlap, C., Koo, J., Ismail, F., Boulias, C., Reid, S., & Phadke, C. P. (2019). Interrater Reliability of the Modified Ashworth Scale with Standardized Movement Speeds: A Pilot Study. Physiotherapy Canada, 71(4), 348-354. https://doi.org/10.3138/ptc-2018-0086

Vancouver

Zurawski E, Behm K, Dunlap C, Koo J, Ismail F, Boulias C, et al. Interrater Reliability of the Modified Ashworth Scale with Standardized Movement Speeds: A Pilot Study. Physiotherapy Canada. 2019;71(4):348-354. doi:10.3138/ptc-2018-0086

BibTeX
@article{Zurawski2019,
  author = {Zurawski, Erica and Behm, Kirsten and Dunlap, Charlotte and Koo, James and Ismail, Farooq and Boulias, Chris and Reid, Shannon and Phadke, Chetan P},
  title = {Interrater Reliability of the Modified Ashworth Scale with Standardized Movement Speeds: A Pilot Study},
  journal = {Physiotherapy Canada},
  year = {2019},
  volume = {71},
  number = {4},
  pages = {348--354},
  doi = {10.3138/ptc-2018-0086}
}
Kostenlos starten →