Interrater reliability in assigning a lung ultrasound score
Australian Critical Care · 2023-09 · 36 (5) · 732-736
DOI: 10.1016/j.aucc.2022.10.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Australian Critical Care, 2023-09. Verfasst von Louise Hansell und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia; Physiotherapy Department, Royal North …. Hauptthemen laut MEDLINE: Lung, Intensive Care Units. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: Lung ultrasound (LUS) for physiotherapists is an emerging bedside tool. The LUS score of aeration presents as a possible means of assessing and monitoring lung aeration associated with respiratory physiotherapy treatments. There are no studies to date that have assessed the interrater reliability (IRR) of physiotherapists assigning the LUS score of aeration. This study assessed the IRR of assigning the LUS score among adult, mechanically ventilated patients in an intensive care unit with a clinical suspicion of acute lobar atelectasis. METHODS: A convenience sample of patients had an LUS performed by a physiotherapist, and images were independently reviewed by two physiotherapists. Each lung zone was assigned an LUS score between 0 and 3 (with 0 being normal aeration and 3 being complete consolidation, presence of effusion, or pneumothorax). IRR was assessed using the kappa statistic. RESULTS: A total of 1032 LUS images were obtained. Assigning of the LUS across all lung zones demonstrated substantial agreement with kappa 0.685 (95% confidence interval: 0.650, 0.720). Right (0.702 [0.653, 0.751]) and left (0.670 [0.619, 0.721]) lung zones also demonstrated substantial agreement. CONCLUSION: We found substantial IRR between physiotherapists in assigning the LUS score in a mechanically ventilated adult population in the intensive care unit. AUSTRALIAN NEW ZEALAND CLINICAL TRIALS REGISTRATION NUMBER: ACTRN12619000783123.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia; Physiotherapy Department, Royal North Shore Hospital, St Leonards, Sydney, Australia. Electronic address: Lo…
- Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia. Electronic address: Maree.Milross@sydney.edu.au.
- Malcolm Fisher Department of Intensive Care Medicine, Royal North Shore Hospital, Sydney, Australia; Division of Critical Care, The George Institute for Global Health, University of New South Wales, Sydney, Australia; N…
- Division of Critical Care, The George Institute for Global Health, University of New South Wales, Sydney, Australia; Department of Anaesthesia and Perioperative Medicine, Westmead Hospital, Australia. Electronic address…
- Physiotherapy Department, St Vincent's Hospital, Sydney, Australia. Electronic address: georgentou@yahoo.com.
Zitieren
APA
Hansell, L., Milross, M., Delaney, A., Tian, D. H., & Ntoumenopoulos, G. (2023). Interrater reliability in assigning a lung ultrasound score. Australian Critical Care, 36(5), 732-736. https://doi.org/10.1016/j.aucc.2022.10.008
Vancouver
Hansell L, Milross M, Delaney A, Tian DH, Ntoumenopoulos G. Interrater reliability in assigning a lung ultrasound score. Australian Critical Care. 2023;36(5):732-736. doi:10.1016/j.aucc.2022.10.008
BibTeX
@article{Hansell2023,
author = {Hansell, Louise and Milross, Maree and Delaney, Anthony and Tian, David H and Ntoumenopoulos, George},
title = {Interrater reliability in assigning a lung ultrasound score},
journal = {Australian Critical Care},
year = {2023},
volume = {36},
number = {5},
pages = {732--736},
doi = {10.1016/j.aucc.2022.10.008}
}
EUVIMED