EUVIMEDEUVIMED entdecken
Crossref

Metric Causes of Refractive Errors of the Eye

Petr Veselý, Pavel Beneš, Jana Sokolová Šidlová, Petra Záděrová, Hana Došková

Czech and Slovak Ophthalmology · 17.09.2025

DOI: 10.31348/2025/40 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Czech and Slovak Ophthalmology, online erschienen am 17.09.2025. Verfasst von Petr Veselý und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Refractive Errors, Axial Length, Eye.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To confirm current knowledge about the causes of refractive errors in adults. To evaluate the influence of systemic, i.e., primary curvature and, on the other hand, axial causes of refractive errors of the eye, in comparison with the Gullstrand model of the eye expressed by axial length and corneal curvature ratio. Material and Methods: The basic sample included 60 eyes of 30 subjects with an average age of 22.3 ±1.1 years. There were 3 men and 27 women in the group. They were young, generally healthy individuals, without serious eye pathologies. The basic sample was divided into research (n = 36) and control group (n = 24). We measured the axial length of the eye using the IOL MASTER 500 optical biometer (Carl Zeiss Meditec, Jena, Germany). We measured the topographic and keratometric values ​​of the cornea using the Pentacam HR device (Oculus GmbH, Wetzlar, Germany). We obtained the objective refraction values ​​by measuring them on a standard instrument automatic refractometer TRK-1P (Topcon Corp., Tokyo, Japan). We determined the axial length of the eye (AXD), the average value of keratometry (KRT) and the spherical equivalent of the refractive error (SE) as significant variables. The evaluation of variables was carried out by comparison with the Gullstrand model of the eye.

Results

We calculated the ratios of the median axial length of the eye and the median keratometry in the research group with myopia (AXD/KRTM = 3.18 with IQR 0.1) and the control group (AXD/KRTK = 2.93 with IQR 0.1). The difference between the two groups was statistically significant (p < 0.001). The percentage expression of axial and curvature causes of ametropia was 72/28% in the myopic group and 83/17% in the control group.

Conclusion

Our study confirmed that the AXD/KRT parameter is a significant indicator of the cause of the refractive state of the eye, with the important influence of axial length on this parameter.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Refractive ErrorsAxial Length, EyeHumansFemaleMaleYoung AdultAdultCorneaCorneal TopographyRefraction, Ocular

Stichwörter der Autor:innen

Pentacamaxial lengthkeratometryoptical biometerrefractometry

Zitieren

APA

Veselý, P., Beneš, P., Sokolová Šidlová, J., Záděrová, P., & Došková, H. (2025). Metric Causes of Refractive Errors of the Eye. Czech and Slovak Ophthalmology. https://doi.org/10.31348/2025/40

Vancouver

Veselý P, Beneš P, Sokolová Šidlová J, Záděrová P, Došková H. Metric Causes of Refractive Errors of the Eye. Czech and Slovak Ophthalmology. 2025. doi:10.31348/2025/40

BibTeX
@article{Vesel2025,
  author = {Veselý, Petr and Beneš, Pavel and Sokolová Šidlová, Jana and Záděrová, Petra and Došková, Hana},
  title = {Metric Causes of Refractive Errors of the Eye},
  journal = {Czech and Slovak Ophthalmology},
  year = {2025},
  doi = {10.31348/2025/40}
}
Kostenlos starten →