EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Zulu ocular biometry differs fundamentally from that of Europeans – A modelling analysis

Veronica Lockett-Ruiz iD, Tanya Evans iD, Rafael Navarro iD, Khathutshelo Percy Mashige, Jos J Rozema iD

Ophthalmic and Physiological Optics · 2025

DOI: 10.1111/opo.70000 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Veronica Lockett-Ruiz und 4 weiteren Autor:innen. Beteiligte Einrichtung: INMA-CSIC and Universidad de Zaragoza, Zaragoza, Spain. Hauptthemen laut MEDLINE: Axial Length, Eye, Biometry, Lens, Crystalline, Refraction, Ocular. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 Marie Skłodowska-Curie Actions, South African Medical Research Council, Department of Higher Education and Training.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The accuracy of ocular refraction calculations depends on reliable biometry and the validity of the models upon which the calculations are based. Most models are based on European eyes, so their validity in sub‐Saharan Africans may be questioned, potentially contributing to suboptimal postoperative outcomes. Hence, this study developed an optical eye model tailored to a Zulu cohort.

Methods

Ocular biometry data were collected from 192 near‐emmetropic (i.e., non‐cycloplegic spherical equivalent within ±1D) young individuals of Zulu descent in Durban, South Africa. Key biometric parameters, including axial length, corneal thickness, anterior chamber depth, crystalline lens thickness and vitreous chamber depth, were measured and input into Bennett's and Royston's equations to develop the eye model. This model was subsequently compared to the eyes of 32 near‐emmetropic young European adults that were used previously to help develop the SyntEyes model. Statistical analysis was performed to identify significant differences in ocular structural parameters between the models.

Results

Zulu eyes exhibited marked differences compared to European eyes. On average, Zulu eyes had deeper anterior chambers (+0.28 mm, t ‐test, p < 0.001), thinner crystalline lenses (−0.19 mm, p < 0.001) and lower corneal power (−0.83 D, p = 0.001). However, the total ocular power of Zulu eyes was greater due to a more powerful crystalline lens (+2.60 D, p < 0.001). No significant difference in refractive error or axial length was observed between the two populations.

Conclusions

The ocular biometry of the Zulu population differs significantly from that of the European population, particularly in corneal and crystalline lens power, lens thickness and anterior chamber depth. This has important implications for intraocular lens power calculations, glaucoma risk assessment and other diagnostic procedures. Accurate, population‐specific references are essential for optimising vision correction and enhancing ophthalmic healthcare outcomes in regions with populations underrepresented in the literature.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Axial Length, EyeBiometryLens, CrystallineRefraction, OcularRefractive ErrorsWhite PeopleSouthern African PeopleAdultFemaleHumansMaleYoung AdultAnterior ChamberCorneaEuropean PeopleSouth Africa

Stichwörter der Autor:innen

Africanaxial lengthcorneal thicknesseyeocular biometryrefractive error

Autor:innen und Institutionen

  • INMA-CSIC and Universidad de Zaragoza, Zaragoza, Spain.
  • Department of Optometry, University of Johannesburg, Johannesburg, South Africa.
  • School of Health Sciences, University of KwaZulu-Natal, Durban, South Africa.
  • Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium.
  • Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium.
  • Institute for Medical Informatics, Statistics and Epidemiology (IMISE), Leipzig University, Leipzig, Germany.

ORCID-Profile: Veronica Lockett-Ruiz, Tanya Evans, Rafael Navarro, Jos J Rozema

Förderung

  • H2020 Marie Skłodowska-Curie Actions
  • South African Medical Research Council
  • Department of Higher Education and Training

Zitieren

APA

Lockett-Ruiz, V., Evans, T., Navarro, R., Mashige, K. P., & Rozema, J. J. (2025). Zulu ocular biometry differs fundamentally from that of Europeans – A modelling analysis. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.70000

Vancouver

Lockett-Ruiz V, Evans T, Navarro R, Mashige KP, Rozema JJ. Zulu ocular biometry differs fundamentally from that of Europeans – A modelling analysis. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.70000

BibTeX
@article{LockettRuiz2025,
  author = {Lockett-Ruiz, Veronica and Evans, Tanya and Navarro, Rafael and Mashige, Khathutshelo Percy and Rozema, Jos J},
  title = {Zulu ocular biometry differs fundamentally from that of Europeans – A modelling analysis},
  journal = {Ophthalmic and Physiological Optics},
  year = {2025},
  doi = {10.1111/opo.70000}
}
Kostenlos starten →