EUVIMEDEUVIMED entdecken
Crossref

Rat tissue responses to dacarbazine-containing implants made of cross-linked polyurethane of different densities

N. A. Galatenko, R. A. Rozhnova, D. V. Kuliesh, V. D. Denisenko, A. P. Maletskyy, N. M. Bigun

Oftalmologicheskii Zhurnal · 22.08.2022 · 99 (4) · 40-48

DOI: 10.31288/oftalmolzh202244048 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oftalmologicheskii Zhurnal, online erschienen am 24.08.2022. Verfasst von N. A. Galatenko und 5 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Restorative orbital and periorbital surgeries require implantable materials containing antimicrobial and anticancer medications.

Purpose

To assess rat tissue responses to dacarbazine-containing implants made of cross-linked polyurethane of different densities. Material and Methods: Dacarbazine (DC)-containing polyurethane-urea foam (PUUF) implants were a subject of research. We studied the dynamics of DC release from these implant samples. Soft tissue cellular responses to the developed composites were assessed through the implantation of the latter in Wistar rats.

Results

We found that the number of open pores impacts implant survival. There was no substantial difference in DC release between the PUUF samples with a DC weight percent of 1% and those with a DC weight percent of 0.5% at incubation days 1 to 3. At days 5, 7 and 14, an increase in DC release was higher in the former samples than in the latter samples (64% versus 55%). In animals with a subcutaneously implanted PUUF sample, there was histological evidence of (a) formation of a capsule and tight network of blood vessels surrounding an implanted sample at day 3, and (b) separation of the implanted material from the surrounding tissues by a wide cuff of lymphocytes and a thick connective tissue capsule (CTC) at day 7.

Conclusion

The number of open pores impacts DC release and the speed of connective tissue ingrowth into the porous matrix. It was found that a CTC formed around all implants at early time points and at day 30, which in combination with the presence of DC in composite materials resulted in long-term cellular inflammation at the implant placement site.

Zitieren

APA

Galatenko, N. A., Rozhnova, R. A., Kuliesh, D. V., Denisenko, V. D., Maletskyy, A. P., & Bigun, N. M. (2022). Rat tissue responses to dacarbazine-containing implants made of cross-linked polyurethane of different densities. Oftalmologicheskii Zhurnal, 99(4), 40-48. https://doi.org/10.31288/oftalmolzh202244048

Vancouver

Galatenko NA, Rozhnova RA, Kuliesh DV, Denisenko VD, Maletskyy AP, Bigun NM. Rat tissue responses to dacarbazine-containing implants made of cross-linked polyurethane of different densities. Oftalmologicheskii Zhurnal. 2022;99(4):40-48. doi:10.31288/oftalmolzh202244048

BibTeX
@article{Galatenko2022,
  author = {Galatenko, N. A. and Rozhnova, R. A. and Kuliesh, D. V. and Denisenko, V. D. and Maletskyy, A. P. and Bigun, N. M.},
  title = {Rat tissue responses to dacarbazine-containing implants made of cross-linked polyurethane of different densities},
  journal = {Oftalmologicheskii Zhurnal},
  year = {2022},
  volume = {99},
  number = {4},
  pages = {40--48},
  doi = {10.31288/oftalmolzh202244048}
}