Conversion to Sinus Rhythm in Refractory Atrial Fibrillation Patients after Atrioventricular Node Ablation with Conduction System Pacing
Reviews in Cardiovascular Medicine · 24.11.2023 · 24 (11)
DOI: 10.31083/j.rcm2411333 ↗Kurz gefasst
Fachartikel in der Zeitschrift Reviews in Cardiovascular Medicine, online erschienen am 24.11.2023. Verfasst von Maja Ivanovski und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background: “Ablate and pace” strategy is a reasonable treatment option in refractory atrial fibrillation (AF) when sinus rhythm (SR) cannot be achieved with catheter ablation or pharmacological therapy. Atrioventricular node ablation (AVNA) combined with conduction system pacing (CSP), with left bundle branch pacing (LBBP) or His bundle pacing (HBP), is gaining recognition since it offers the most physiological activation of the left ventricle. However, the incidence of conversion to SR after AVNA with CSP is not known. The purpose of the investigation was to determine the incidence of spontaneous conversion to SR and its predicting factors in patients undergoing CSP and AVNA.
Methods
Consecutive refractory symptomatic AF patients undergoing AVNA with CSP at our institution between June 2018 and December 2022 were retrospectively analyzed. Twelve lead electrocardiogram (ECG) recordings were analyzed at each outpatient follow-up visit. Echocardiographic and clinical parameters were assessed at baseline and six months after the implantation.
Results
Sixty-eight patients (male 42.6%, age 71 ± 8 years, left ventricular ejection fraction 40 ± 15%) were included. Thirty-seven patients (54.4%) received HBP and 31 (45.6%) LBBP. During follow-up, spontaneous conversion to SR was registered in 6 patients (8.8%); 3 in the HBP group and 3 in the LBBP group. Baseline characteristics of patients who converted to SR did not differ from non-sinus rhythm (NSR) patients except for left atrial volume index (LAVI), which was significantly smaller in the SR group (45 mL/m2 (41–51) vs. 60 mL/m2 (52–75); p = 0.002). Multiple regression model confirmed an inverse association between LAVI and conversion to SR even after considering other clinically relevant covariates (odds ratio 1.273, p = 0.028). At follow-up, LAVI did not change in any group (SR: p = 0.345; NSR: p = 0.508). Improvement in New York Heart Association (NYHA) class was comparable in both groups.
Conclusions
Spontaneous conversion to SR after AVNA combined with CSP is not uncommon, especially in patients with smaller left atria. Further studies are warranted to clarify which patients should be considered for initial dual-chamber device implantation to provide atrio-ventricular synchrony in case of SR restoration.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia.
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia.
Zitieren
APA
Ivanovski, M., Mrak, M., Zupan Mežnar, A., & Žižek, D. (2023). Conversion to Sinus Rhythm in Refractory Atrial Fibrillation Patients after Atrioventricular Node Ablation with Conduction System Pacing. Reviews in Cardiovascular Medicine, 24(11). https://doi.org/10.31083/j.rcm2411333
Vancouver
Ivanovski M, Mrak M, Zupan Mežnar A, Žižek D. Conversion to Sinus Rhythm in Refractory Atrial Fibrillation Patients after Atrioventricular Node Ablation with Conduction System Pacing. Reviews in Cardiovascular Medicine. 2023;24(11). doi:10.31083/j.rcm2411333
BibTeX
@article{Ivanovski2023,
author = {Ivanovski, Maja and Mrak, Miha and Zupan Mežnar, Anja and Žižek, David},
title = {Conversion to Sinus Rhythm in Refractory Atrial Fibrillation Patients after Atrioventricular Node Ablation with Conduction System Pacing},
journal = {Reviews in Cardiovascular Medicine},
year = {2023},
volume = {24},
number = {11},
doi = {10.31083/j.rcm2411333}
}
EUVIMED