EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Left atrial mechanics following left bundle branch area pacing vs. non-conduction system pacing after atrioventricular node ablation in atrial fibrillation

Ziad Zalaquett, Roy Chung iD, Yuichiro Okushi iD, Joe Demian iD, Brian Griffin, Pasquale Santangeli iD, Patrick Collier iD, Niraj Varma iD

Europace · 02.06.2026 · 28 (6)

DOI: 10.1093/europace/euag116 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 11.05.2026. Verfasst von Ziad Zalaquett und 7 weiteren Autor:innen. Beteiligte Einrichtung: Section of Cardiovascular Imaging, Cardiovascular Medicine, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Sydell and Arnold Miller Famil…. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Atrioventricular nodal (AVN) ablation with ventricular pacing for rate control benefits patients with atrial fibrillation (AF) and rapid ventricular response.1 Pacing mode matters. Right ventricular pacing (RVP) may result in heart failure by forcing ventricular dyssynchrony.2 In contrast, biventricular pacing (BiV) post-AVN ablation improved survival.3 Left bundle branch area pacing (LBBAP) may confer additional benefit, as it restores normal sinus rhythm (NSR) in some ‘refractory’ AF patients undergoing AVN ablation.4 The mechanism underlying this phenomenon is incompletely understood. We hypothesized that changes in left atrial (LA) function would accompany ventricular pacing in AF patients following AVN ablation, and the direction of these changes would differ between LBBAP and non-conduction system pacing (non-CSP). We retrospectively analysed patients with refractory, uncontrolled AF who underwent AVN ablation and either LBBAP or non-CSP (RVP, leadless, or BiV) with interpretable pre- and post-procedural echocardiograms during follow-up (2019–23) at the Cleveland Clinic. Demographic and clinical characteristics were extracted from electronic medical records. The study received IRB approval. LBBAP technique followed standard procedure using lumenless leads as previously described5 [left ventricle (LV) activation time of 33 ms and presence of LBB potential]. Non-CSP included RVP (apical or septal) and BiV (coronary sinus lead with an RV lead). The primary objective was to compare the impact of LBBAP vs. non-CSP on echocardiographic measures of LA function. Standard volumetric and functional parameters were assessed pre- and post-procedure. LA maximal and minimal volumes were measured and indexed to body surface area, and LA emptying fraction calculated accordingly. LA strain [reservoir (LASr), conduit (LAScd), and contractile (LASct)] was assessed from apical four-chamber views and averaged over three consecutive cycles in AF, and LV global longitudinal strain (GLS) from apical two-, three-, and four-chamber views using TomTec software, with manual adjustment as needed. All measurements demonstrated excellent intra- and inter-observer reliability (intra-class correlation coefficient >0.80). Spontaneous occurrence of NSR was assessed during follow-up (mean 2.7 ± 1.5 years). Normality of continuous variables was assessed using the Shapiro–Wilk test. Pre- and post-pacing comparisons were performed using paired t-tests. The effect of LBBAP vs. non-CSP on post-pacing echocardiographic parameters was evaluated using analysis of covariance (ANCOVA) with adjustment for baseline values and relevant covariates. A P-value of

Schlagwörter

Stichwörter der Autor:innen

Atrial fibrillationLeft bundle branch area pacingNodal ablationSpeckle-tracking echocardiography

Autor:innen und Institutionen

  • Section of Cardiovascular Imaging, Cardiovascular Medicine, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Sydell and Arnold Miller Family Heart and Vascular Institute, The Cleveland Clinic Foundation, 9500…
  • Section of Pacing and Cardiac Electrophysiology, Cardiovascular Medicine, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.

ORCID-Profile: Roy Chung, Yuichiro Okushi, Joe Demian, Pasquale Santangeli, Patrick Collier, Niraj Varma

Zitieren

APA

Zalaquett, Z., Chung, R., Okushi, Y., Demian, J., Griffin, B., Santangeli, P., Collier, P., & Varma, N. (2026). Left atrial mechanics following left bundle branch area pacing vs. non-conduction system pacing after atrioventricular node ablation in atrial fibrillation. Europace, 28(6). https://doi.org/10.1093/europace/euag116

Vancouver

Zalaquett Z, Chung R, Okushi Y, Demian J, Griffin B, Santangeli P, et al. Left atrial mechanics following left bundle branch area pacing vs. non-conduction system pacing after atrioventricular node ablation in atrial fibrillation. Europace. 2026;28(6). doi:10.1093/europace/euag116

BibTeX
@article{Zalaquett2026,
  author = {Zalaquett, Ziad and Chung, Roy and Okushi, Yuichiro and Demian, Joe and Griffin, Brian and Santangeli, Pasquale and Collier, Patrick and Varma, Niraj},
  title = {Left atrial mechanics following left bundle branch area pacing vs. non-conduction system pacing after atrioventricular node ablation in atrial fibrillation},
  journal = {Europace},
  year = {2026},
  volume = {28},
  number = {6},
  doi = {10.1093/europace/euag116}
}
Kostenlos starten →