EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Mitigating Fire-Induced Degradation in Concrete through Carbon Fiber Incorporation: An Experimental and Statistical Study

Wisam Abdulkadhim Hussein, Manar Hamid Jasim, Waleed Muwafaq Al-Aloosi, Mohammed S. Radhi, Zainab Al-Khafaji, Mayadah Falah

Journal of Building Material Science · 23.11.2026 · 8 (4) · 139-155

DOI: 10.30564/jbms.v8i4.116000 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Building Material Science, online erschienen am 23.11.2026. Verfasst von Wisam Abdulkadhim Hussein und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High temperatures can cause severe damage to the load-bearing capacity and internal integrity of concrete. The residual performance of 1:2:4 concrete with carbon fibers based on polyacrylonitrile at 0%, 1% and 2% of the cement mass was investigated in this work. 36 100-mm cube specimens were cured for 28 days and exposed for 24 h to nominal temperatures of 25, 250, 500 and 750 °C. Residual compressive strength and direct-transmission ultrasonic pulse velocity (UPV) were tested after cooling. Differences among the 12 treatment groups were estimated using one-way analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) test. The compressive strength decreased with the increase in temperature, while the residual strength increased with the addition of carbon fiber. The control, 1% and 2% fiber mixes showed strengths of 7, 10 and 11 MPa, respectively, at 500 °C with 40.0%, 55.6% and 55.0% retention of the ambient temperature strengths. The 2% fiber mix was 57.1% stronger than the control. The residual strength at 750 °C was 5 MPa (25.0% retention), which is double the control strength of 2.5 MPa (14.3% retention). Control-mixture UPV dropped from 4.54 km/s (25 °C) to 3.30 km/s (750 °C). The velocity of the 500 °C fiber mixtures was 4.10 km/s, and for the control, 3.80 km/s. The ANOVA analysis showed that the treatment groups were significantly different from each other (F = 1,114.96, p < 0.0001). The highest residual strength of the three conditions tested was observed for the 2 % carbon fiber.

Zitieren

APA

Hussein, W. A., Jasim, M. H., Al-Aloosi, W. M., Radhi, M. S., Al-Khafaji, Z., & Falah, M. (2026). Mitigating Fire-Induced Degradation in Concrete through Carbon Fiber Incorporation: An Experimental and Statistical Study. Journal of Building Material Science, 8(4), 139-155. https://doi.org/10.30564/jbms.v8i4.116000

Vancouver

Hussein WA, Jasim MH, Al-Aloosi WM, Radhi MS, Al-Khafaji Z, Falah M. Mitigating Fire-Induced Degradation in Concrete through Carbon Fiber Incorporation: An Experimental and Statistical Study. Journal of Building Material Science. 2026;8(4):139-155. doi:10.30564/jbms.v8i4.116000

BibTeX
@article{Hussein2026,
  author = {Hussein, Wisam Abdulkadhim and Jasim, Manar Hamid and Al-Aloosi, Waleed Muwafaq and Radhi, Mohammed S. and Al-Khafaji, Zainab and Falah, Mayadah},
  title = {Mitigating Fire-Induced Degradation in Concrete through Carbon Fiber Incorporation: An Experimental and Statistical Study},
  journal = {Journal of Building Material Science},
  year = {2026},
  volume = {8},
  number = {4},
  pages = {139--155},
  doi = {10.30564/jbms.v8i4.116000}
}
Kostenlos starten →