Planning-stage sizing of a PV – wind – battery – diesel microgrid under joint reliability and operational CO₂-intensity constraints

Reji Kurien Thomas

Journal of Energy Systems · 2026-06-24 · 10 (2) · 97-110

DOI: 10.30521/jes.1895217 ↗

At a glance

Journal article in Journal of Energy Systems, published online on 2026-06-24. Written by Reji Kurien Thomas. 43 references. Funded by: TOL Biotech, India.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

This study proposes a planning-stage techno-economic framework for sizing a standalone PV–wind–battery–diesel microgrid under simultaneous reliability and operational carbon-intensity constraints. Candidate system configurations defined by photovoltaic capacity, wind capacity, battery storage size, and diesel generator rating are evaluated using an hourly energy-balance simulation over a full annual cycle. Supply reliability is enforced through a loss-of-power-supply probability (LPSP) constraint of 1%, while environmental performance is controlled via a delivered-energy CO₂-intensity threshold of 0.25 kg CO₂/kWh. Renewable resource and load profiles were obtained from publicly available datasets to support transparency and reproducibility. System performance metrics included unmet load, renewable curtailment, battery utilization, diesel dispatch, fuel consumption, and levelized cost of electricity (LCOE). Results showed that feasible configurations achieved LCOE values between 0.19 – 0.31 USD/kWh and operational CO₂ intensity between 0.14 – 0.29 kg CO₂/kWh. Increasing renewable penetration and battery storage reduced diesel energy contribution by 52 – 78%. The framework provides a transparent and reproducible screening approach for identifying technically feasible and economically viable hybrid microgrid configurations prior to detailed optimization.

Funding

  • TOL Biotech, India

Cite

APA

Thomas, R. K. (2026). Planning-stage sizing of a PV – wind – battery – diesel microgrid under joint reliability and operational CO₂-intensity constraints. Journal of Energy Systems, 10(2), 97-110. https://doi.org/10.30521/jes.1895217

Vancouver

Thomas RK. Planning-stage sizing of a PV – wind – battery – diesel microgrid under joint reliability and operational CO₂-intensity constraints. Journal of Energy Systems. 2026;10(2):97-110. doi:10.30521/jes.1895217

BibTeX
@article{Thomas2026,
  author = {Thomas, Reji Kurien},
  title = {Planning-stage sizing of a PV – wind – battery – diesel microgrid under joint reliability and operational CO₂-intensity constraints},
  journal = {Journal of Energy Systems},
  year = {2026},
  volume = {10},
  number = {2},
  pages = {97--110},
  doi = {10.30521/jes.1895217}
}