EUVIMEDEUVIMED entdecken
Open Access

ISIT-QA: In Silico Imaging Trial to Evaluate a Low-Count Quantitative SPECT Method Across Multiple Scanner–Collimator Configurations for 223 Ra-Based Radiopharmaceutical Therapies

Zekun Li, Nadia Benabdallah, Jingqin Luo, Richard L Wahl, Daniel L J Thorek, Abhinav K Jha

Journal of Nuclear Medicine · 2024

DOI: 10.2967/jnumed.123.266719 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine, 2024. Verfasst von Zekun Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Washington University, St. Louis, Missouri. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Radiopharmaceuticals, Computer Simulation, Radium. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Personalized dose-based treatment planning requires accurate and reproducible noninvasive measurements to ensure safety and effectiveness. Dose estimation using SPECT is possible but challenging for alpha (α)-particle-emitting radiopharmaceutical therapy (α-RPT) because of complex γ-emission spectra, extremely low counts, and various image-degrading artifacts across a plethora of scanner-collimator configurations. Through the incorporation of physics-based considerations and skipping of the potentially lossy voxel-based reconstruction step, a recently developed projection-domain low-count quantitative SPECT (LC-QSPECT) method has the potential to provide reproducible, accurate, and precise activity concentration and dose measures across multiple scanners, as is typically the case in multicenter settings. To assess this potential, we conducted an in silico imaging trial to evaluate the LC-QSPECT method for a 223Ra-based α-RPT, with the trial recapitulating patient and imaging system variabilities.

Methods

A virtual imaging trial titled In Silico Imaging Trial for Quantitation Accuracy (ISIT-QA) was designed with the objectives of evaluating the performance of the LC-QSPECT method across multiple scanner-collimator configurations and comparing performance with a conventional reconstruction-based quantification method. In this trial, we simulated 280 realistic virtual patients with bone-metastatic castration-resistant prostate cancer treated with 223Ra-based α-RPT. The trial was conducted with 9 simulated SPECT scanner-collimator configurations. The primary objective of this trial was to evaluate the reproducibility of dose estimates across multiple scanner-collimator configurations using LC-QSPECT by calculating the intraclass correlation coefficient. Additionally, we compared the reproducibility and evaluated the accuracy of both considered quantification methods across multiple scanner-collimator configurations. Finally, the repeatability of the methods was evaluated in a test-retest study.

Results

In this trial, data from 268 223RaCl2 treated virtual prostate cancer patients, with a total of 2,903 lesions, were used to evaluate LC-QSPECT. LC-QSPECT provided dose estimates with good reproducibility across the 9 scanner-collimator configurations (intraclass correlation coefficient > 0.75) and high accuracy (ensemble average values of recovery coefficients ranged from 1.00 to 1.02). Compared with conventional reconstruction-based quantification, LC-QSPECT yielded significantly improved reproducibility across scanner-collimator configurations, accuracy, and test-retest repeatability ([Formula: see text]

Conclusion

LC-QSPECT provides reproducible, accurate, and repeatable dose estimations in 223Ra-based α-RPT as evaluated in ISIT-QA. These findings provide a strong impetus for multicenter clinical evaluations of LC-QSPECT in dose quantification for α-RPTs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Emission-Computed, Single-PhotonRadiopharmaceuticalsComputer SimulationRadiumHumansMaleImage Processing, Computer-AssistedReproducibility of ResultsQuality Control

Stichwörter der Autor:innen

in silico imaging triallow-count quantitative SPECTreproducibilitytheranosticsα-particle–emitting radiopharmaceutical therapy

Substanzen

RadiopharmaceuticalsRadiumRadium-223

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Washington University, St. Louis, Missouri.
  • Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri.
  • Program in Quantitative Molecular Therapeutics, Washington University, St. Louis, Missouri.
  • Siteman Cancer Center, Washington University, St. Louis, Missouri.
  • Division of Public Health Sciences, Department of Surgery, Washington University, St. Louis, Missouri; and.
  • Division of Biostatistics, Washington University, St. Louis, Missouri.

Förderung

  • NCI NIH HHS
  • NIBIB NIH HHS

Zitieren

APA

Li, Z., Benabdallah, N., Luo, J., Wahl, R. L., Thorek, D. L. J., & Jha, A. K. (2024). ISIT-QA: In Silico Imaging Trial to Evaluate a Low-Count Quantitative SPECT Method Across Multiple Scanner–Collimator Configurations for 223 Ra-Based Radiopharmaceutical Therapies. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.123.266719

Vancouver

Li Z, Benabdallah N, Luo J, Wahl RL, Thorek DLJ, Jha AK. ISIT-QA: In Silico Imaging Trial to Evaluate a Low-Count Quantitative SPECT Method Across Multiple Scanner–Collimator Configurations for 223 Ra-Based Radiopharmaceutical Therapies. Journal of Nuclear Medicine. 2024. doi:10.2967/jnumed.123.266719

BibTeX
@article{Li2024,
  author = {Li, Zekun and Benabdallah, Nadia and Luo, Jingqin and Wahl, Richard L and Thorek, Daniel L J and Jha, Abhinav K},
  title = {ISIT-QA: In Silico Imaging Trial to Evaluate a Low-Count Quantitative SPECT Method Across Multiple Scanner–Collimator Configurations for 223 Ra-Based Radiopharmaceutical Therapies},
  journal = {Journal of Nuclear Medicine},
  year = {2024},
  doi = {10.2967/jnumed.123.266719}
}
Kostenlos starten →