Quantitative Reconstructions for Renal Sestamibi SPECT/CT: A Modeled Comparison of 360-Degree Versus 180-Degree Acquisitions
Nuklearmedizin - NuclearMedicine · 01.10.2026 · 65 (05) · 323-327
DOI: 10.1055/a-2914-2268 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.10.2026. Verfasst von Jorge D Oldan und 10 weiteren Autor:innen. Beteiligte Einrichtung: University of North Carolina, Division of Molecular Imaging and Therapeutics, Department of Radiology, NC, USA, Chapel Hill. Hauptthemen laut MEDLINE: Technetium Tc 99m Sestamibi, Single Photon Emission Computed Tomography Computed Tomography, Kidney Neoplasms, Image Interpretation, Computer-Assisted. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
99m Tc-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) is a cost-effective and accurate means of characterizing indeterminate renal masses. This is scant literature on 99m Tc-sestamibi protocol optimization. We investigated the difference between modeled, quantitative 180-degree and 360-degree acquisitions for 99mTc-sestamibi SPECT/CT in a cohort of 50 patients who were prospectively enrolled on a scan-and-resect protocol. Two experienced, dual-boarded observers rated each renal mass for image quality (1–5 scale) and diagnosis (benign to malignant, 1–5 scale) in a blinded, randomized order. Ordinal logistic regression was used, incorporating random intercepts for patient and reader; inter-observer variability was assessed. Image quality ratings were significantly higher for 360-degree acquisitions versus 180-degree (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- University of North Carolina, Division of Molecular Imaging and Therapeutics, Department of Radiology, NC, USA, Chapel Hill.
- SUNY Upstate University Hospital, Department of Interventional Radiology, NY, USA, Syracuse.
- Johns Hopkins University School of Medicine, The Russell H. Morgan Department of Radiology and Radiological Science, MD, USA, Baltimore.
- University of North Carolina, Biostatistics, Department of Radiology, NC, USA, Chapel Hill.
- Johns Hopkins University School of Medicine, The James Buchanan Brady Urological Institute and Department of Urology, MD, USA, Baltimore.
- Pennsylvania State University College of Medicine, Department of Radiology, PA, USA, Hershey.
Zitieren
APA
Oldan, J. D., Schroeder, J. A., Jeyasingam, M., Solnes, L. B., Mondragon, E. L., Benefield, T., Allaf, M. E., Tulchinsky, M., Gorin, M. A., Du, Y., & Rowe, S. P. (2026). Quantitative Reconstructions for Renal Sestamibi SPECT/CT: A Modeled Comparison of 360-Degree Versus 180-Degree Acquisitions. Nuklearmedizin - NuclearMedicine, 65(05), 323-327. https://doi.org/10.1055/a-2914-2268
Vancouver
Oldan JD, Schroeder JA, Jeyasingam M, Solnes LB, Mondragon EL, Benefield T, et al. Quantitative Reconstructions for Renal Sestamibi SPECT/CT: A Modeled Comparison of 360-Degree Versus 180-Degree Acquisitions. Nuklearmedizin - NuclearMedicine. 2026;65(05):323-327. doi:10.1055/a-2914-2268
BibTeX
@article{Oldan2026,
author = {Oldan, Jorge D and Schroeder, Jennifer A and Jeyasingam, Mathurika and Solnes, Lilja B and Mondragon, Emi Lou and Benefield, Thad and Allaf, Mohammad E and Tulchinsky, Mark and Gorin, Michael A and Du, Yong and Rowe, Steven P},
title = {Quantitative Reconstructions for Renal Sestamibi SPECT/CT: A Modeled Comparison of 360-Degree Versus 180-Degree Acquisitions},
journal = {Nuklearmedizin - NuclearMedicine},
year = {2026},
volume = {65},
number = {05},
pages = {323--327},
doi = {10.1055/a-2914-2268}
}
EUVIMED