Performance Evaluation of the uMI Panorama PET/CT System in Accordance with the National Electrical Manufacturers Association NU 2-2018 Standard
Journal of Nuclear Medicine · 2024-04 · 65 (4) · 652-658
DOI: 10.2967/jnumed.123.265929 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Medicine, online erschienen am 22.02.2024. Verfasst von Guiyu Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, Xi'an, China. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
The uMI Panorama is a novel PET/CT system using silicon photomultiplier and application-specific integrated circuit technologies and providing exceptional spatial and time-of-flight (TOF) resolutions. The objective of this study was to assess the physical performance of the uMI Panorama in accordance with the National Electrical Manufacturers Association (NEMA) NU 2-2018 standard.
Methods
Spatial resolution, sensitivity, count rate performance, accuracy, image quality, and TOF resolution were evaluated in accordance with the guidelines outlined in the NEMA NU 2-2018 standard. Energy resolution was determined using the same dataset acquired for the count rate performance evaluation. Images from a Hoffman brain phantom, a mini-Derenzo phantom, and 3 patient studies were evaluated to demonstrate system performance.
Results
The transaxial spatial resolution at full width at half maximum was measured as 2.88 mm with a 1-cm offset from the center axial field of view. The sensitivity at the center axial field of view was 20.1 kcps/MBq. At an activity concentration of 73.0 kBq/mL, the peak noise-equivalent count rate (NECR) reached 576 kcps with a scatter fraction of approximately 33.2%. For activity concentrations at or below the peak NECR, the maximum relative count rate error among all slices remained consistently below 3%. When assessed using the NEMA image quality phantom, overall image contrast recovery ranged from 63.2% to 88.4%, whereas background variability ranged from 4.2% to 1.1%. TOF resolution was 189 ps at 5.3 kBq/mL and was consistently lower than 200 ps for activity concentrations at or below the peak NECR. The patient studies demonstrated that scans at 2 min/bed produced images characterized by low noise and high contrast. Clear delineation of nuclei, spinal cords, and other substructures of the brain was observed in the brain PET images. Conclusion: uMI Panorama, the world's first commercial PET system with sub-200-ps TOF resolution, demonstrated fine spatial and fast TOF resolutions, robust count rate performance, and high quantification accuracy across a wide range of activity levels. This advanced technology offers enhanced diagnostic capability for detecting small and low-contrast lesions while showing promising potential under high-count-rate imaging scenarios.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, Xi'an, China.
- Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, Xi'an, China 13909245902@163.com fmmukf@qq.com.
Zitieren
APA
Li, G., Ma, W., Li, X., Yang, W., Quan, Z., Ma, T., Wang, J., Wang, Y., Kang, F., & Wang, J. (2024). Performance Evaluation of the uMI Panorama PET/CT System in Accordance with the National Electrical Manufacturers Association NU 2-2018 Standard. Journal of Nuclear Medicine, 65(4), 652-658. https://doi.org/10.2967/jnumed.123.265929
Vancouver
Li G, Ma W, Li X, Yang W, Quan Z, Ma T, et al. Performance Evaluation of the uMI Panorama PET/CT System in Accordance with the National Electrical Manufacturers Association NU 2-2018 Standard. Journal of Nuclear Medicine. 2024;65(4):652-658. doi:10.2967/jnumed.123.265929
BibTeX
@article{Li2024,
author = {Li, Guiyu and Ma, Wenhui and Li, Xiang and Yang, Weidong and Quan, Zhiyong and Ma, Taoqi and Wang, Junling and Wang, Yunya and Kang, Fei and Wang, Jing},
title = {Performance Evaluation of the uMI Panorama PET/CT System in Accordance with the National Electrical Manufacturers Association NU 2-2018 Standard},
journal = {Journal of Nuclear Medicine},
year = {2024},
volume = {65},
number = {4},
pages = {652--658},
doi = {10.2967/jnumed.123.265929}
}
EUVIMED