EUVIMEDEUVIMED entdecken
Crossref

Clinical Pilot of a Deep Learning Elastic Registration Algorithm to Improve Misregistration Artifact and Image Quality on Routine Oncologic PET/CT

Jordan H Chamberlin, Joshua Schaefferkoetter, James Hamill, Ismail M Kabakus, Kevin P Horn, Jim O'Doherty, Saeed Elojeimy

Academic Radiology · 2025-02 · 32 (2) · 1015-1025

DOI: 10.1016/j.acra.2024.09.044 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2025-02. Verfasst von Jordan H Chamberlin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Medical University of South Carolina, Charleston, South Carolina, USA. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Artifacts, Deep Learning, Neoplasms. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: Misregistration artifacts between the PET and attenuation correction CT (CTAC) exams can degrade image quality and cause diagnostic errors. Deep learning (DL)-warped elastic registration methods have been proposed to improve misregistration errors. MATERIALS AND METHODS: 30 patients undergoing routine oncologic examination (20 18F-FDG PET/CT and 10 64Cu-DOTATATE PET/CT) were retrospectively identified and compared using unmodified CTAC, and a DL-augmented spatial transformation CT attenuation map. Primary endpoints included differences in subjective image quality and standardized uptake values (SUV). Exams were randomized to reduce reader bias, and three radiologists rated image quality across six anatomic sites using a modified Likert scale. Measures of local bias and lesion SUV were also quantitatively evaluated. RESULTS: The DL attenuation correction methods were associated with higher image quality and reduced misregistration artifacts (Mean 18F-FDG quality rating=3.5-3.8 for DL vs 3.2-3.5 for standard reconstruction (STD); Mean 64Cu-DOTATATE quality rating= 3.2-3.4 for DL vs 2.1-3.3; P < 0.05 for STD, for all except 64Cu-DOTATATE inferior spleen). Percent change in superior liver SUVmean for 18F-FDG and 64Cu-DOTATATE were 5.3 ± 4.9 and 8.2 ± 4.1%, respectively. Measures of signal-to-noise ratio were significantly improved for the DL over STD (Hepatopulmonary index (HPI) [18F-FDG] = 4.5 ± 1.2 vs 4.0 ± 1.1, P < 0.001; HPI [64Cu-DOTATATE] = 16.4 ± 16.9 vs 12.5 ± 5.5, P = 0.039). CONCLUSION: Deep learning elastic registration for CT attenuation correction maps on routine oncology PET/CT decreases misregistration artifacts, with a greater impact on PET scans with longer acquisition times.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyArtifactsDeep LearningNeoplasmsHumansFemaleMalePilot ProjectsMiddle AgedRetrospective StudiesFluorodeoxyglucose F18AgedAlgorithmsRadiopharmaceuticalsOrganometallic CompoundsAdult

Stichwörter der Autor:innen

Artificial IntelligenceDeep LearningElastic RegistrationMisregistration ArtifactPET/CT

Substanzen

Fluorodeoxyglucose F18RadiopharmaceuticalsOrganometallic Compounds

Autor:innen und Institutionen

  • Department of Radiology, Medical University of South Carolina, Charleston, South Carolina, USA.
  • Siemens Medical Solutions USA, Inc., 810 Innovation Drive, Knoxville, Tennessee 37932, USA.
  • Department of Radiology, Medical University of South Carolina, Charleston, South Carolina, USA; Siemens Medical Solutions USA, Inc., 40 Liberty Blvd, Malvern, Pennsylvania 19355, USA.
  • Department of Radiology, Medical University of South Carolina, Charleston, South Carolina, USA. Electronic address: elojeim@gmail.com.

Zitieren

APA

Chamberlin, J. H., Schaefferkoetter, J., Hamill, J., Kabakus, I. M., Horn, K. P., O'Doherty, J., & Elojeimy, S. (2025). Clinical Pilot of a Deep Learning Elastic Registration Algorithm to Improve Misregistration Artifact and Image Quality on Routine Oncologic PET/CT. Academic Radiology, 32(2), 1015-1025. https://doi.org/10.1016/j.acra.2024.09.044

Vancouver

Chamberlin JH, Schaefferkoetter J, Hamill J, Kabakus IM, Horn KP, O'Doherty J, et al. Clinical Pilot of a Deep Learning Elastic Registration Algorithm to Improve Misregistration Artifact and Image Quality on Routine Oncologic PET/CT. Academic Radiology. 2025;32(2):1015-1025. doi:10.1016/j.acra.2024.09.044

BibTeX
@article{Chamberlin2025,
  author = {Chamberlin, Jordan H and Schaefferkoetter, Joshua and Hamill, James and Kabakus, Ismail M and Horn, Kevin P and O'Doherty, Jim and Elojeimy, Saeed},
  title = {Clinical Pilot of a Deep Learning Elastic Registration Algorithm to Improve Misregistration Artifact and Image Quality on Routine Oncologic PET/CT},
  journal = {Academic Radiology},
  year = {2025},
  volume = {32},
  number = {2},
  pages = {1015--1025},
  doi = {10.1016/j.acra.2024.09.044}
}
Kostenlos starten →