EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wound architectural analysis of 1.8mm microincision cataract surgery using spectral domain OCT

Benedito Antônio de Sousa, Anderson Teixeira, Camila Salaroli, Nonato Souza, Lucy Gomes

International Journal of Clinical and Experimental Ophthalmology · 2019

DOI: 10.29328/journal.ijceo.1001020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Clinical and Experimental Ophthalmology, 2019. Verfasst von Benedito Antônio de Sousa und 4 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Analyze Microincision Cataract surgery wound using Fourier-Domain optical coherence tomography.

Setting

Medical School of Medicine, Catholic University of Brasilia, Brasília, Brazil.

Design

Prospective comparative observational study Methods: Forty eyes were included in this prospective study divided in two groups: with contact lens (CL) and without contact lens (WCL). A line scan pattern of the corneal incisions were acquired using a Spectral domain OCT system immediately after the surgery, and at postoperative days 1, 7 and 30. Incisions were analyzed regarding length, location, angle, architecture, and anatomic imperfections.

Results

All incisions were located temporal or nasal superiorly. The average wound length was 1.28 + 0.18mm and the mean incision angle was 49 + 9 degrees. The average wound length of the WCL group mean was 1.24 + 0.17 mm and the mean incision angle was 51 + 8 degrees. Comparing groups for the length and the angle, the incisions measurements were not statistically significant. Anatomic imperfections were observed at the first day postoperative in 12 eyes for CL group and in 13 eyes for the WCL group. No patient presented endophthalmitis during the follow-up.

Conclusion

Epithelial imperfection was observed in two patients in the WCL group with spontaneous resolution. The CL group had the highest length and lowest angle of corneal incision. Using contact lens to prevent wound construction imperfection appears not to be a good option. Further studies using a greater number of patients with an architectural analysis of clear corneal incisions are needed to confirm these preliminary results.

Zitieren

APA

Sousa, B. A. D., Teixeira, A., Salaroli, C., Souza, N., & Gomes, L. (2019). Wound architectural analysis of 1.8mm microincision cataract surgery using spectral domain OCT. International Journal of Clinical and Experimental Ophthalmology. https://doi.org/10.29328/journal.ijceo.1001020

Vancouver

Sousa BAD, Teixeira A, Salaroli C, Souza N, Gomes L. Wound architectural analysis of 1.8mm microincision cataract surgery using spectral domain OCT. International Journal of Clinical and Experimental Ophthalmology. 2019. doi:10.29328/journal.ijceo.1001020

BibTeX
@article{Sousa2019,
  author = {Sousa, Benedito Antônio de and Teixeira, Anderson and Salaroli, Camila and Souza, Nonato and Gomes, Lucy},
  title = {Wound architectural analysis of 1.8mm microincision cataract surgery using spectral domain OCT},
  journal = {International Journal of Clinical and Experimental Ophthalmology},
  year = {2019},
  doi = {10.29328/journal.ijceo.1001020}
}
Kostenlos starten →