EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Bimanual Microincision Cataract Surgery Using a 0.7 mm Sub-millimeter Incision

Krishna Vaitheeswaran, Preetinder Kaur, Monika Nadar

Indian Journal of Cataract and Refractive Surgery · 2024-07 · 1 (3) · 218-222

DOI: 10.4103/icrs.icrs_18_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Cataract and Refractive Surgery, online erschienen am 27.03.2026. Verfasst von Krishna Vaitheeswaran und 2 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A bstract Background: Small incisions for cataract surgery are associated with advantages of wound stability, improved control, reduced chamber turbulence, and early visual rehabilitation. However, true sub-millimeter incision cataract surgery is seldom used in clinical practice due to surgical challenges and concerns of visual results.

Purpose

To study the visual and surgical results of microincision cataract surgery using a modified bimanual technique using 25-G instruments through a sub-millimeter 0.7 mm incision.

Design

Observational case series. Materials and Methods: Fifteen patients underwent cataract surgery using a modified bimanual microincision technique. The technique uses a 25-G phacoemulsification tip with the irrigation sleeve removed. Irrigation was achieved through a separately placed 25-G anterior chamber maintainer. A third 25-G incision was made for introducing the chopper. The nucleus was cracked using two choppers before the phacoemulsification procedure was started. The phacoemulsification was performed in the pulse mode.

Results

There were no intraoperative complications, and the anterior chamber remained stable throughout the procedure in all patients. The mean effective phaco time was 2.24 s. Three patients with grade 4 nuclei had transient corneal striate keratopathy that resolved in a week. All patients were followed up for a minimum period of 3 months. Postoperative visual acuity and the aberration profile were assessed. All patients had a distance visual acuity of 6/12 or better at the last follow-up.

Conclusion

The modified microincision cataract surgical technique provides an enhanced quality and safety of cataract surgery using a sub-millimeter incision of 0.7 mm.

Zitieren

APA

Vaitheeswaran, K., Kaur, P., & Nadar, M. (2024). Bimanual Microincision Cataract Surgery Using a 0.7 mm Sub-millimeter Incision. Indian Journal of Cataract and Refractive Surgery, 1(3), 218-222. https://doi.org/10.4103/icrs.icrs_18_25

Vancouver

Vaitheeswaran K, Kaur P, Nadar M. Bimanual Microincision Cataract Surgery Using a 0.7 mm Sub-millimeter Incision. Indian Journal of Cataract and Refractive Surgery. 2024;1(3):218-222. doi:10.4103/icrs.icrs_18_25

BibTeX
@article{Vaitheeswaran2024,
  author = {Vaitheeswaran, Krishna and Kaur, Preetinder and Nadar, Monika},
  title = {Bimanual Microincision Cataract Surgery Using a 0.7 mm Sub-millimeter Incision},
  journal = {Indian Journal of Cataract and Refractive Surgery},
  year = {2024},
  volume = {1},
  number = {3},
  pages = {218--222},
  doi = {10.4103/icrs.icrs_18_25}
}
Kostenlos starten →