EUVIMEDEUVIMED entdecken
Crossref

Real-world experience of transoesophageal echocardiography for detection of clinically significant persistent foramen ovale

Peter Wilmshurst, Matthew Pearson, Kevin Walsh, W Lindsay Morrison

Diving and Hyperbaric Medicine Journal · 30.06.2026 · 56 (2) · 148-153

DOI: 10.28920/dhm56.2.148-153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diving and Hyperbaric Medicine Journal, online erschienen am 30.06.2026. Verfasst von Peter Wilmshurst und 3 weiteren Autor:innen. Beteiligte Einrichtung: United Kingdom Diving Medical Committee (UKDMC), United Kingdom. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Foramen Ovale, Patent. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transoesophageal echocardiography (TOE) is claimed to be the investigation of choice for detecting a persistent foramen ovale (PFO) with almost 100% diagnostic accuracy. If true, TOE would detect all large/clinically significant PFOs.

Methods

Retrospective analysis to determine the sensitivity of TOE for detection of clinically significant PFOs. Patients were from a consecutive series of 150 patients who had transcatheter closure of a PFO following events attributed to paradoxical embolism (decompression sickness or stroke). In each patient, transthoracic echocardiogram with bubble contrast showed a clinically significant atrial right-to-left shunt. The data reported are from the sub-group of the 150 patients with a clinically significant PFO who also had a TOE performed in other hospitals.

Results

Twenty seven of 150 consecutive patients had a total of 31 TOEs performed at 22 United Kingdom regional cardiac centres. TOE failed to detect a PFO in 17 of the 27 patients. Four patients had a TOE on two separate occasions and in each case both of the TOEs failed to show a PFO. TOE gave a false negative test in 21 of 31 investigations (sensitivity 32%). The mean PFO diameter was 9.4 mm (median 9 mm, range 5−16 mm) in the 21 patients in whom balloon sizing was performed and 9.8 mm (median 10 mm, range 5−16 mm) in the 13 patients in whom balloon sizing was performed and a TOE failed to show a PFO.

Conclusions

These finding demonstrate that the precision of TOE for detecting a PFO in real world clinical practice is considerably lower than generally believed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, TransesophagealForamen Ovale, PatentHumansRetrospective StudiesSensitivity and SpecificityFemaleFalse Negative ReactionsMaleMiddle AgedAdult

Stichwörter der Autor:innen

BubblesDecompression sicknessDivingEchocardiographyPersistent foramen ovaleStrokeTranscatheter closure

Autor:innen und Institutionen

  • United Kingdom Diving Medical Committee (UKDMC), United Kingdom.
  • Corresponding author: Dr Peter Wilmshurst United Kingdom Diving Medical Committee, United Kingdom, peter.wilmshurst@doctors.org.uk.
  • Shrewsbury and Telford NHS Hospital Trust, Shrewsbury SY3 8XQ, United Kingdom.
  • University College Dublin, Dublin, Ireland.
  • Our Lady's Hospital for Sick Children, Dublin 12, Ireland.
  • Liverpool Heart and Chest Hospital, Liverpool L14 3PE, United Kingdom.

Zitieren

APA

Wilmshurst, P., Pearson, M., Walsh, K., & Morrison, W. L. (2026). Real-world experience of transoesophageal echocardiography for detection of clinically significant persistent foramen ovale. Diving and Hyperbaric Medicine Journal, 56(2), 148-153. https://doi.org/10.28920/dhm56.2.148-153

Vancouver

Wilmshurst P, Pearson M, Walsh K, Morrison WL. Real-world experience of transoesophageal echocardiography for detection of clinically significant persistent foramen ovale. Diving and Hyperbaric Medicine Journal. 2026;56(2):148-153. doi:10.28920/dhm56.2.148-153

BibTeX
@article{Wilmshurst2026,
  author = {Wilmshurst, Peter and Pearson, Matthew and Walsh, Kevin and Morrison, W Lindsay},
  title = {Real-world experience of transoesophageal echocardiography for detection of clinically significant persistent foramen ovale},
  journal = {Diving and Hyperbaric Medicine Journal},
  year = {2026},
  volume = {56},
  number = {2},
  pages = {148--153},
  doi = {10.28920/dhm56.2.148-153}
}
Kostenlos starten →