EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pre-interventional transesophageal echocardiography as a reliable predictor of residual shunt following patent foramen ovale closure

Tobias Harm, Monika Zdanyte, Andreas Goldschmied, Álvaro Petersen Uribe, Marc Reinert, Juergen Schreieck, Parwez Aidery, Dominik Rath, Tobias Geisler, Meinrad Paul Gawaz, Michal Droppa

Clinical Research in Cardiology · 2026

DOI: 10.1007/s00392-025-02713-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Research in Cardiology, 2026. Verfasst von Tobias Harm und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology and Angiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Otfried-Müller-Straße 10, Tübingen, 72076, …. Hauptthemen laut MEDLINE: Foramen Ovale, Patent, Echocardiography, Transesophageal, Cardiac Catheterization. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Gesellschaft für Kardiologie-Herz und Kreislaufforschung., Universitätsklinikum Tübingen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Closure of a patent foramen ovale (PFO) is an effective strategy in the prevention of recurrent stroke after cryptogenic stroke. Residual shunt (RS) is a common issue following PFO closure and may affect safety and efficacy. Transesophageal echocardiography (TEE) is the key diagnostic tool, but standardized assessment of morphological parameters to prevent RS remains challenging.

Aims

In this study, we investigate the diagnostic value of different anatomical parameters assessed by TEE to predict RS after PFO closure.

Methods

We consecutively enrolled five-hundred and twenty-seven ( n = 527) patients undergoing PFO closure. We performed pre-interventional TEE, and after PFO closure, we then screened for RS by TEE at 6-month follow-up.

Results

Pre-interventional TEE measures of PFO morphology revealed significant differences in patients with RS in comparison to those with closed PFO. Incidence of RS was significantly more frequent in patients with atrial septum aneurysm ( p = 0.022) and increasing PFO size ( p = 0.025). In patients with RS, we found significantly increased length ( p = 0.005) of septum primum and PFO tunnel ( p = 0.036) as well as excursion ( p = 0.005) of septum primum. By training machine learning models on TEE parameters, stratification of PFO morphology resulted in high diagnostic accuracy to predict RS after PFO closure.

Conclusions

Our study elucidates that a baseline characterization of PFO morphology using TEE improves diagnostic precision to identify patients with RS after PFO closure. A standardized approach might thus enhance the efficacy and safety of transcatheter PFO closure. Prediction of complete closure might reduce complications and allow for a more refined patient selection and treatment. Graphical Abstract Prediction of peri-device leak in patients PFO and paradoxical embolism undergoing percutaneous PFO closure. Workflow of this study investigating the association of morphological determinants with an increased incidence of residual shunting assessed through transesophageal echocardiography.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Foramen Ovale, PatentEchocardiography, TransesophagealCardiac CatheterizationHumansFemaleMaleMiddle AgedPredictive Value of TestsAgedFollow-Up StudiesTreatment OutcomeRetrospective StudiesAdultSeptal Occluder Device

Stichwörter der Autor:innen

Paradoxical embolismPatent foramen ovalePeri-device leakResidual shuntTranscatheter closureTransesophageal echocardiography

Autor:innen und Institutionen

  • Department of Cardiology and Angiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Otfried-Müller-Straße 10, Tübingen, 72076, Germany.
  • Department of Cardiology and Angiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Otfried-Müller-Straße 10, Tübingen, 72076, Germany. michal.droppa@med.uni-tuebingen.de.

Förderung

  • Deutsche Gesellschaft für Kardiologie-Herz und Kreislaufforschung.
  • Universitätsklinikum Tübingen

Zitieren

APA

Harm, T., Zdanyte, M., Goldschmied, A., Uribe, Á. P., Reinert, M., Schreieck, J., Aidery, P., Rath, D., Geisler, T., Gawaz, M. P., & Droppa, M. (2026). Pre-interventional transesophageal echocardiography as a reliable predictor of residual shunt following patent foramen ovale closure. Clinical Research in Cardiology. https://doi.org/10.1007/s00392-025-02713-5

Vancouver

Harm T, Zdanyte M, Goldschmied A, Uribe ÁP, Reinert M, Schreieck J, et al. Pre-interventional transesophageal echocardiography as a reliable predictor of residual shunt following patent foramen ovale closure. Clinical Research in Cardiology. 2026. doi:10.1007/s00392-025-02713-5

BibTeX
@article{Harm2026,
  author = {Harm, Tobias and Zdanyte, Monika and Goldschmied, Andreas and Uribe, Álvaro Petersen and Reinert, Marc and Schreieck, Juergen and Aidery, Parwez and Rath, Dominik and Geisler, Tobias and Gawaz, Meinrad Paul and Droppa, Michal},
  title = {Pre-interventional transesophageal echocardiography as a reliable predictor of residual shunt following patent foramen ovale closure},
  journal = {Clinical Research in Cardiology},
  year = {2026},
  doi = {10.1007/s00392-025-02713-5}
}