Review of saturation decompression procedures used in commercial diving
Diving and Hyperbaric Medicine Journal · 2024
DOI: 10.28920/dhm54.1.23-38 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Diving and Hyperbaric Medicine Journal, 2024. Verfasst von Jean-Pierre Imbert und 3 weiteren Autor:innen. Beteiligte Einrichtung: Divetech, 1543 chemin des vignasses, 06410 Biot, France. Hauptthemen laut MEDLINE: Diving, Decompression Sickness. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
This is a review of commercial heliox saturation decompression procedures. The scope does not include compression, storage depth or bell excursion dive procedures. The objectives are to: identify the sources of the procedures; trace their evolution; describe the current practice; and detect relevant trends.
Methods
Eleven international commercial diving companies provided their diving manuals for review under a confidentiality agreement.
Results
Modern commercial diving saturation procedures are derived from a small number of original procedures (United States Navy, Comex, and NORSOK). In the absence of relevant scientific studies since the late 80’s, the companies have empirically adapted these procedures according to their needs and experience. Such adaptation has caused differences in decompression rates shallower than 60 msw, decompression rest stops and the decision to decompress linearly or stepwise. Nevertheless, the decompression procedures present a remarkable homogeneity in chamber PO2 and daily decompression rates when deeper than 60 msw. The companies have also developed common rules of good practice; no final decompression should start with an initial ascending excursion; a minimum hold is required before starting a final decompression after an excursion dive. Recommendation is made for the divers to exercise during decompression.
Conclusions
We observed a trend towards harmonisation within the companies that enforce international procedures, and, between companies through cooperation inside the committees of the industry associations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Divetech, 1543 chemin des vignasses, 06410 Biot, France.
- Corresponding author: Jean Pierre Imbert, Divetech, 1543 ch des vignasses 0641Biot, France, jpi.divetech@gmail.com.
- Hyperbaric and Tissue Viability Unit, Gozo General Hospital, Malta.
- CHU de Nice, Hôpital Pasteur, 30 avenue de la voie romaine, 06001 Nice, France.
- International SOS, Forest Grove House, Foresterhill Road, Aberdeen, AB25 2ZP, UK.
Zitieren
APA
Imbert, J. P., Matity, L., Massimelli, J. Y., & Bryson, P. (2024). Review of saturation decompression procedures used in commercial diving. Diving and Hyperbaric Medicine Journal. https://doi.org/10.28920/dhm54.1.23-38
Vancouver
Imbert JP, Matity L, Massimelli JY, Bryson P. Review of saturation decompression procedures used in commercial diving. Diving and Hyperbaric Medicine Journal. 2024. doi:10.28920/dhm54.1.23-38
BibTeX
@article{Imbert2024,
author = {Imbert, Jean-Pierre and Matity, Lyubisa and Massimelli, Jean-Yves and Bryson, Philip},
title = {Review of saturation decompression procedures used in commercial diving},
journal = {Diving and Hyperbaric Medicine Journal},
year = {2024},
doi = {10.28920/dhm54.1.23-38}
}
EUVIMED