Measuring whole-body inert gas uptake and washout during submersion
Diving and Hyperbaric Medicine Journal · 30.06.2026 · 56 (2) · 137-147
DOI: 10.28920/dhm56.2.137-147 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diving and Hyperbaric Medicine Journal, online erschienen am 30.06.2026. Verfasst von Oscar Plogmark und 3 weiteren Autor:innen. Beteiligte Einrichtung: Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Respiratory Medicine and Allergology, Lund, Sweden. Hauptthemen laut MEDLINE: Nitrogen, Noble Gases, Diving.
Abstract (Originalsprache)
Introduction
Quantifying inert gas uptake and washout is critical for understanding decompression sickness (DCS). However, the limited amount of data has made it difficult to integrate inert gas kinetics into risk models for DCS. Measuring whole-body inert gas kinetics during submersion is technically challenging. This study presents a novel method for quantifying inert gas uptake and washout in human divers using a rebreather-based system.
Methods
During constant-depth diving with a closed-circuit system that maintains a constant oxygen partial pressure, changes in buoyancy will reflect the kinetics of inert gas. Two divers completed four dives each, with a bottom phase at 2.5 bar and a decompression phase at 1.3 bar or 1.4 bar. Load cell data were converted into equivalent changes in volume of nitrogen standardised for temperature and pressure (VN2, STP). Power analysis was conducted to quantify the resolution by which the method could detect nitrogen uptake and washout volumes.
Results
Distinct uptake and washout curves were obtained, comparable to previous studies using other techniques. Mean VN2 uptake during the bottom phase was 0.96 L (SD 0.29), while mean washout during decompression was 0.67 L (SD 0.26). The minimal mean detectable difference (MDD) with eight dives was 0.28 L for the bottom phase and 0.26 L for the decompression phase, considering standard 80% power and a 0.05 significance level.
Conclusions
This novel method quantifies inert gas kinetics during submersion with acceptable precision and accuracy. It could facilitate the collection of inert gas kinetics data during submersion, potentially yielding valuable correlations with the risk of DCS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Respiratory Medicine and Allergology, Lund, Sweden.
- Swedish Armed Forces Diving and Naval Medicine Center, Swedish Armed Forces, Karlskrona, Sweden.
- Corresponding author: Dr Oscar Plogmark, Sölvegatan 19, 221 85 Lund, Sweden, oscar.plogmark@med.lu.se.
- Lund University, Faculty of Engineering, Department of Automatic Control, Lund, Sweden.
- Kungälv Hospital, Department of Anesthesia and Intensive care, Kungälv, Sweden.
- Blekinge Institute of Technology, Department of Mathematics and Natural Science, Karlskrona, Sweden.
ORCID-Profile: Oscar Plogmark
Zitieren
APA
Plogmark, O., Soltesz, K., Hjelte, C., & Frånberg, O. (2026). Measuring whole-body inert gas uptake and washout during submersion. Diving and Hyperbaric Medicine Journal, 56(2), 137-147. https://doi.org/10.28920/dhm56.2.137-147
Vancouver
Plogmark O, Soltesz K, Hjelte C, Frånberg O. Measuring whole-body inert gas uptake and washout during submersion. Diving and Hyperbaric Medicine Journal. 2026;56(2):137-147. doi:10.28920/dhm56.2.137-147
BibTeX
@article{Plogmark2026,
author = {Plogmark, Oscar and Soltesz, Kristian and Hjelte, Carl and Frånberg, Oskar},
title = {Measuring whole-body inert gas uptake and washout during submersion},
journal = {Diving and Hyperbaric Medicine Journal},
year = {2026},
volume = {56},
number = {2},
pages = {137--147},
doi = {10.28920/dhm56.2.137-147}
}