EUVIMEDEUVIMED entdecken
Open Access

Pulmonary oxygen toxicity breath markers after heliox diving to 81 metres

Feiko Jm de Jong, Paul Brinkman, Thijs T Wingelaar, Pieter-Jan Am van Ooij, Robert A van Hulst

Diving and Hyperbaric Medicine Journal · 2023

DOI: 10.28920/dhm53.4.340-344 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diving and Hyperbaric Medicine Journal, 2023. Verfasst von Feiko Jm de Jong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Royal Netherlands Navy Diving and Submarine Medical Centre, 1780 CA, Den Helder, The Netherlands. Hauptthemen laut MEDLINE: Diving, Hyperoxia. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulmonary oxygen toxicity (POT), an adverse reaction to an elevated partial pressure of oxygen in the lungs, can develop as a result of prolonged hyperbaric hyperoxic conditions. Initially starting with tracheal discomfort, it results in pulmonary symptoms and ultimately lung fibrosis. Previous studies identified several volatile organic compounds (VOCs) in exhaled breath indicative of POT after various wet and dry hyperbaric hypoxic exposures, predominantly in laboratory settings. This study examined VOCs after exposures to 81 metres of seawater by three navy divers during operational heliox diving. Univariate testing did not yield significant results. However, targeted multivariate analysis of POT-associated VOCs identified significant (P = 0.004) changes of dodecane, tetradecane, octane, methylcyclohexane, and butyl acetate during the 4 h post-dive sampling period. No airway symptoms or discomfort were reported. This study demonstrates that breath sampling can be performed in the field, and VOCs indicative of oxygen toxicity are exhaled without clinical symptoms of POT, strengthening the belief that POT develops on a subclinical-to-symptomatic spectrum. However, this study was performed during an actual diving operation and therefore various confounders were introduced, which were excluded in previous laboratory studies. Future studies could focus on optimising sampling protocols for field use to ensure uniformity and reproducibility, and on establishing dose-response relationships.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DivingHyperoxiaHumansReproducibility of ResultsOxygenHelium

Stichwörter der Autor:innen

Diving researchHeliumMilitary divingUnit pulmonary toxic doseVolatile organic compounds

Substanzen

helioxOxygenHelium

Autor:innen und Institutionen

  • Royal Netherlands Navy Diving and Submarine Medical Centre, 1780 CA, Den Helder, The Netherlands.
  • Department of Anesthesiology, Amsterdam University Medical Center, location AMC, 1100 DD, Amsterdam, The Netherlands.
  • Corresponding author: Feiko JM de Jong, Royal Netherlands Navy Diving and Submarine Medical Centre, Rijkszee-en Marinehaven, Postbus 10.000, 1780 CA, Den Helder, The Netherlands, ORCiD: 0009-0008-9804-8307, fjm.d.jong@m…
  • Department of Pulmonology, Amsterdam University Medical Center, location AMC, 1100 DD, Amsterdam, The Netherlands.

Zitieren

APA

de Jong, F. J., Brinkman, P., Wingelaar, T. T., van Ooij, P. A., & van Hulst, R. A. (2023). Pulmonary oxygen toxicity breath markers after heliox diving to 81 metres. Diving and Hyperbaric Medicine Journal. https://doi.org/10.28920/dhm53.4.340-344

Vancouver

de Jong FJ, Brinkman P, Wingelaar TT, van Ooij PA, van Hulst RA. Pulmonary oxygen toxicity breath markers after heliox diving to 81 metres. Diving and Hyperbaric Medicine Journal. 2023. doi:10.28920/dhm53.4.340-344

BibTeX
@article{deJong2023,
  author = {de Jong, Feiko Jm and Brinkman, Paul and Wingelaar, Thijs T and van Ooij, Pieter-Jan Am and van Hulst, Robert A},
  title = {Pulmonary oxygen toxicity breath markers after heliox diving to 81 metres},
  journal = {Diving and Hyperbaric Medicine Journal},
  year = {2023},
  doi = {10.28920/dhm53.4.340-344}
}
Kostenlos starten →