EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Measurement of Temperature, CO₂ Concentration, and Humidity in Food Spoilage Gas Using an Electroplated SnO₂ Resistive Sensor

Ridlo Hajatulloh, Moh. Toifur, Aliaman Aliaman, Indra Budi Setiawan, Okimustava Okimustava, Eko Susanto

Lontar Physics Today · 17.08.2026 · 5 (2) · 297-312

DOI: 10.26877/lpt.v5i2.594 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lontar Physics Today, online erschienen am 17.08.2026. Verfasst von Ridlo Hajatulloh und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Food spoilage is accompanied by changes in environmental parameters, including temperature, carbon dioxide (CO₂) concentration, and relative humidity, which can influence the electrical response of metal oxide semiconductor sensors. This study aimed to fabricate an SnO₂ resistive sensor by electroplating and evaluate its electrical response to environmental variations during food spoilage. The SnO₂ sensing layer was deposited on a Cu substrate by electroplating at 6.0 V and an electrolyte temperature of 40 °C, followed by thermal oxidation. The fabricated sensor was tested in a sealed chamber containing a food sample undergoing natural spoilage, while temperature, CO₂ concentration, relative humidity, and sensor resistance were simultaneously monitored. The results showed that the sensor resistance generally decreased with increasing temperature, CO₂ concentration, and relative humidity. Regression analysis revealed a strong relationship between sensor resistance and temperature (R² = 0.8729), whereas relative humidity showed a moderate relationship (R² = 0.5669). The resistance response to CO₂ concentration also exhibited a distinct nonlinear trend associated with the progression of food decomposition. These findings indicate that temperature and CO₂ concentration exert a stronger influence on the electrical response of the electroplated SnO₂ sensor than relative humidity. The fabricated sensor therefore demonstrates potential as a low-cost resistive sensing platform for monitoring environmental changes associated with food spoilage.

Zitieren

APA

Hajatulloh, R., Toifur, M., Aliaman, A., Setiawan, I. B., Okimustava, O., & Susanto, E. (2026). Measurement of Temperature, CO₂ Concentration, and Humidity in Food Spoilage Gas Using an Electroplated SnO₂ Resistive Sensor. Lontar Physics Today, 5(2), 297-312. https://doi.org/10.26877/lpt.v5i2.594

Vancouver

Hajatulloh R, Toifur M, Aliaman A, Setiawan IB, Okimustava O, Susanto E. Measurement of Temperature, CO₂ Concentration, and Humidity in Food Spoilage Gas Using an Electroplated SnO₂ Resistive Sensor. Lontar Physics Today. 2026;5(2):297-312. doi:10.26877/lpt.v5i2.594

BibTeX
@article{Hajatulloh2026,
  author = {Hajatulloh, Ridlo and Toifur, Moh. and Aliaman, Aliaman and Setiawan, Indra Budi and Okimustava, Okimustava and Susanto, Eko},
  title = {Measurement of Temperature, CO₂ Concentration, and Humidity in Food Spoilage Gas Using an Electroplated SnO₂ Resistive Sensor},
  journal = {Lontar Physics Today},
  year = {2026},
  volume = {5},
  number = {2},
  pages = {297--312},
  doi = {10.26877/lpt.v5i2.594}
}
Kostenlos starten →