In Vitro Degradation and Mechanical Performance of Mg AZ31B for Biodegradable Bone Implant Applications
Advance Sustainable Science Engineering and Technology · 15.04.2026 · 8 (2) · 0260207
DOI: 10.26877/asset.v8i2.2652 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advance Sustainable Science Engineering and Technology, online erschienen am 15.04.2026. Verfasst von Slamet Saefudin und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Magnesium AZ31B is a promising biodegradable implant material due to its mechanical properties comparable to natural bone and its ability to degrade in physiological environments, potentially eliminating the need for secondary surgery. However, its rapid degradation can cause a significant loss of mechanical integrity, limiting its use in load-bearing applications. This study investigates the evolution of mechanical properties and surface characteristics of AZ31B during in-vitro immersion in Simulated Body Fluid (SBF). Tensile tests were conducted on triplicate specimens after immersion for 3, 6, and 9 days, while surface morphology and corrosion products were analyzed using SEM–EDX. In addition, pH variation and mass loss were monitored to evaluate corrosion behavior. The results show a progressive decrease in tensile strength from 279.77 ± 5.30 MPa (0 days) to 167.64 ± 2.31 MPa after 9 days of immersion, representing an overall reduction of approximately 40%. This degradation was accompanied by increased surface corrosion, mass loss, and solution alkalization. These findings provide quantitative insight into the relationship between corrosion progression and mechanical degradation of AZ31B, highlighting its time-dependent performance limitations and the need for surface modification strategies in biodegradable implant applications.
Zitieren
APA
Saefudin, S., Purnomo, Subri, M., Pujianto, M. E., Afif, I. Y., & Raharjo, S. (2026). In Vitro Degradation and Mechanical Performance of Mg AZ31B for Biodegradable Bone Implant Applications. Advance Sustainable Science Engineering and Technology, 8(2), 0260207. https://doi.org/10.26877/asset.v8i2.2652
Vancouver
Saefudin S, Purnomo, Subri M, Pujianto ME, Afif IY, Raharjo S. In Vitro Degradation and Mechanical Performance of Mg AZ31B for Biodegradable Bone Implant Applications. Advance Sustainable Science Engineering and Technology. 2026;8(2):0260207. doi:10.26877/asset.v8i2.2652
BibTeX
@article{Saefudin2026,
author = {Saefudin, Slamet and Purnomo and Subri, Muhammad and Pujianto, M. Edi and Afif, Ilham Yustar and Raharjo, Samsudi},
title = {In Vitro Degradation and Mechanical Performance of Mg AZ31B for Biodegradable Bone Implant Applications},
journal = {Advance Sustainable Science Engineering and Technology},
year = {2026},
volume = {8},
number = {2},
pages = {0260207},
doi = {10.26877/asset.v8i2.2652}
}