Background
Hand physiotherapists typically rely on goniometers for manual joint angle assessments, a process that is not only time-consuming but also susceptible to significant variability between therapists, which can lead to inconsistent evaluations, complicating the accurate tracking of a patient's progress.Inter-rater reliability tests are crucial in determining whether these standard assessment tools need to be improved or replaced, to achieve more accurate assessments and ultimately enhance the quality of patient care.
Methods
Participants in the study included five patients hospitalized in the hand department due to movement restrictions and five experienced hand physiotherapists.Following a standardized protocol, flexion and extension of all finger joints were measured, along with other thumb and wrist movements, using identical goniometers and a finger ruler to assess fingernail palm distance (FPD) and fingernail table distance (FNTD).Each joint measurement was performed once by each of the five therapists to evaluate inter-rater reliability.
Results
Results indicate varied inter-rater reliability, with 37.2% of measurements showing poor agreement (ICC < 0.5), 30.2% moderate agreement (0.5 ≤ ICC < 0.75), and 4.7% excellent agreement (ICC ≥ 0.9). Conclusions:Findings underscore the need for improved measurement instruments in clinical settings, suggesting potential benefits from sensor gloves or other electrically based devices to enhance reliability and accuracy in ROM assessments.
Zitieren
APA
Vieira, M., Kögel, A., Stroetmann, M., Wendlandt, R., & Schulz, A. (2026). Low Inter-rater Reliability of Active Hand Joint Range of Motion Measurements When Assessing Hand Function in a Clinical Setting. Archives of Physiotherapy and Rehabilitation. https://doi.org/10.26502/fapr0030
Vancouver
Vieira M, Kögel A, Stroetmann M, Wendlandt R, Schulz A. Low Inter-rater Reliability of Active Hand Joint Range of Motion Measurements When Assessing Hand Function in a Clinical Setting. Archives of Physiotherapy and Rehabilitation. 2026. doi:10.26502/fapr0030
BibTeX
@article{Vieira2026,
author = {Vieira, Margarida and Kögel, Alexander and Stroetmann, Marie and Wendlandt, Robert and Schulz, Arndt-Peter},
title = {Low Inter-rater Reliability of Active Hand Joint Range of Motion Measurements When Assessing Hand Function in a Clinical Setting},
journal = {Archives of Physiotherapy and Rehabilitation},
year = {2026},
doi = {10.26502/fapr0030}
}
EUVIMED