Abstract (Originalsprache)
Introduction: This study evaluates the reliability of dried blood spots (DBS) as an alternative specimen to plasma for HIV viral load monitoring using the COBAS 4800 system (Roche Diagnostics), an approach that has not previously been evaluated on this platform.Viral load testing is essential for monitoring antiretroviral therapy (ART), but plasma-based methods remain limited in resource-constrained settings due to technical and logistical requirements.A comparative analytical study was conducted using paired plasma and DBS samples collected from the same patients living with HIV.Viral loads were quantified using the COBAS 4800 platform.Statistical analyses included Pearson correlation, linear regression, coefficient of determination (R²), and Bland-Altman concordance analysis.The results demonstrated a strong to very strong correlation between plasma and DBS viral loads (r = 0.93-0.986),with R² values up to 97.4%.Bland-Altman analysis showed minimal bias (-0.03 log copies/mL) and clinically acceptable limits of agreement.DBS performance remained high across both low and high viral load categories.This study is the first to demonstrate that DBS can be reliably used for HIV viral load monitoring on the COBAS 4800 system.These findings support the integration of DBS into virological monitoring strategies, particularly in resource-limited settings where access to conventional plasma testing is constrained.
Zitieren
APA
Eric, K. I. (2026). Evaluation of Dried Blood Spots as an Alternative Specimen for HIV Viral Load Monitoring Using the COBAS 4800 System (Roche Diagnostics): A Comparative Study with Plasma. Archives of Clinical and Biomedical Research, 10(3). https://doi.org/10.26502/acbr.50170524
Vancouver
Eric KI. Evaluation of Dried Blood Spots as an Alternative Specimen for HIV Viral Load Monitoring Using the COBAS 4800 System (Roche Diagnostics): A Comparative Study with Plasma. Archives of Clinical and Biomedical Research. 2026;10(3). doi:10.26502/acbr.50170524
BibTeX
@article{Eric2026,
author = {Eric, Kasamba Ilunga},
title = {Evaluation of Dried Blood Spots as an Alternative Specimen for HIV Viral Load Monitoring Using the COBAS 4800 System (Roche Diagnostics): A Comparative Study with Plasma},
journal = {Archives of Clinical and Biomedical Research},
year = {2026},
volume = {10},
number = {3},
doi = {10.26502/acbr.50170524}
}
EUVIMED