Introduction

The progress of labor is traditionally based on clinical examination. The labor curves have been reevaluated due to changes in both population characteristics and obstetric practice and intrapartum ultrasound has emerged as an objective method for the assessment of fetal head station. Aim of study: This study aimed to describe the labor curves in a Greek population using intrapartum ultrasound.

Methods

This was a prospective cohort study of consecutive laboring women in a university obstetric department in Thessaloniki, Greece. Cervical dilatation was examined digitally and the fetal head descent was examined transperineally with the measurements of the angle of progression (AoP) and head-perineum distance (HPD).

Results

Our preliminary data included 50 women. The mean maternal age was 28, the median gestational age was 39 weeks, the median BMI was 29 kg/cm2 and the median of the parity was 1. Twenty-one (42%) had a spontaneous onset of labor, 29 (58%) had an induction of labor, 24 (48%) had epidural analgesia, 32 (64%) received oxytocin, 15 (30%) delivered with a cesarean section and 35 (70%) vaginally. The median duration of labor was 9 hours (IQR: 8, 95% CI: 8.27-11.70). An acceleration phase of maximum mitigation of the angle was noticed, 8.5 hours before birth, cervical dilatation progressed from 4cm to 10cm in 7 hours and the AoP was >100°, at 4.5 hours before birth in the whole study population. In spontaneous deliveries, rapid descent started 3 hours before birth, whereas in induction of labor 8 hours before birth. A slower descent was noticed in women who received epidural analgesia and oxytocin. The fetal head was engaged earlier in nulliparous.

Conclusions

Intrapartum ultrasound allows the objective measurement of fetal head descent both by HPD (mm) and AoP (degrees). Parity, spontaneous onset, epidural and oxytocin affect the labor curve.

Schlagwörter

intrapartum ultrasoundfetal head descentlabor curveangle of progressionhead-perineum distancecervical dilatationlabor inductionepidural analgesiaoxytocinparity

Zitieren

APA

Mitta, K. (2023). Intrapartum ultrasound: a pilot study of its use in Greek labor ward and a review of the literature. Aristotle University of Thessaloniki. https://doi.org/10.26262/heal.auth.ir.347921

Vancouver

Mitta K. Intrapartum ultrasound: a pilot study of its use in Greek labor ward and a review of the literature. Aristotle University of Thessaloniki. 2023. doi:10.26262/heal.auth.ir.347921

BibTeX
@article{Mitta2023,
  author = {Mitta, Kyriaki},
  title = {Intrapartum ultrasound: a pilot study of its use in Greek labor ward and a review of the literature},
  journal = {Aristotle University of Thessaloniki},
  year = {2023},
  doi = {10.26262/heal.auth.ir.347921}
}
Kostenlos starten →