Randomisierte kontrollierte Studie in der Zeitschrift Respiration, online erschienen am 18.11.2024. Verfasst von Taha Huseini und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Thoracic Surgery, CHUM Endoscopic Tracheo-Bronchial and Oesophageal Center (CETOC), Centre de Recherche de Centre Hospitalier de l'Univer…. Hauptthemen laut MEDLINE: Endoscopic Ultrasound-Guided Fine Needle Aspiration, Bronchoscopy, Lymph Nodes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
Introduction
During endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA), a saline-filled balloon placed over the tip of the bronchoscope is used to improve coupling of the ultrasound transducer to the airway wall. However, it is unknown whether it objectively improves image quality or affects procedural outcomes. Our aim was to establish whether the use of a balloon during EBUS impacts image quality, diagnostic yield, procedure duration or complications.
Methods
A pilot randomized control trial of patients undergoing EBUS-TBNA of mediastinal lymph nodes was performed at a single academic center. Patients were randomized to use a saline-filled balloon (versus no balloon use) during EBUS-TBNA of the right lower paratracheal lymph node (station 4R). The EBUS videos were recorded and scored on a 4-point Likert scale by three blinded external reviewers. The primary outcome of this study was ultrasound image quality. Secondary outcomes included diagnostic yield, procedure duration, and complications.
Results
Forty-six patients were randomized. In the balloon group, 61% of patients had an image quality score of “excellent” or “good,” compared to 47% in the no balloon group (p = 0.009). There was no significant difference in diagnostic yield, procedure duration, or complications between the groups.
Conclusion
Inflation of the balloon during EBUS-TBNA at the right lower paratracheal lymph node improves ultrasound image quality but does not impact diagnostic yield, procedure duration, or safety. This study provides a framework for additional studies with complete nodal assessment to determine if balloon use has a clinically meaningful benefit to procedural outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Thoracic Surgery, CHUM Endoscopic Tracheo-Bronchial and Oesophageal Center (CETOC), Centre de Recherche de Centre Hospitalier de l'Université de Montreal (CR-CHUM), Montreal, Québec, Canada.
- Division of Pulmonary and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
Zitieren
APA
Huseini, T., DeMaio, A., Yarmus, L., Pollock, C., Katz, A., Nasir, B., Majid, A., Soder, S., & Liberman, M. (2024). The Impact of Balloon Use during Endobronchial Ultrasound: A Randomized Pilot Study. Respiration, 1-9. https://doi.org/10.1159/000542448
Vancouver
Huseini T, DeMaio A, Yarmus L, Pollock C, Katz A, Nasir B, et al. The Impact of Balloon Use during Endobronchial Ultrasound: A Randomized Pilot Study. Respiration. 2024:1-9. doi:10.1159/000542448
BibTeX
@article{Huseini2024,
author = {Huseini, Taha and DeMaio, Andrew and Yarmus, Lonny and Pollock, Clare and Katz, Amit and Nasir, Basil and Majid, Adnan and Soder, Stephan and Liberman, Moishe},
title = {The Impact of Balloon Use during Endobronchial Ultrasound: A Randomized Pilot Study},
journal = {Respiration},
year = {2024},
pages = {1--9},
doi = {10.1159/000542448}
}
EUVIMED