EUVIMEDEUVIMED entdecken
Crossref

Ultra-low Dose Computed Tomography for Pneumonia in the Emergency Department: A Feasibility Study

Danilo Bianco, Tarso Acoorsi, José de Souza, Eduardo Mello, Joselito Silva, Telles, Gustavo, Rodrigo Caruso Chate, Andre Santos, Renato Moron, Fernando Mattos, Adriana Telles und 9 weitere

Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · 02.10.2023

DOI: 10.25748/arp.33024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT), erschienen am 02.10.2023. Verfasst von Danilo Bianco und 20 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The role of ultra-low-dose chest CT (ULDCT) in the emergency department is unknown.

Purpose

This study sought to examine feasibility of ULDCT in adults presenting to the emergency department for whom pneumonia was suspected. Radiation dose and time interval between medical request and ULDCT results were measured, antibiotic prescriptions were correlated.

Methods

Between October 2017 and December 2018, we prospectively enrolled consecutive healthy adult patients in a single-center for whom community-acquired pneumonia was suspected and for whom no definitive diagnosis was possible by clinical judgment. Exclusion criteria comprised all chronic conditions that could impact severity and interpretation of image.

Results

131 eligible patients (mean age 43.5 years; 57% men) were enrolled to ULDCT. Eighteen (13.7%) patients were excluded. Average CT radiation dose was 0.14 mSv. Time interval between medical request and ultra-low-dose chest CT result was 43 minutes. Only 15.9% of patients with negative CT received antibiotics.

Conclusion

Ultra-low-dose chest CT was feasible for almost all patients in a group of healthy adults presenting to the emergency department with suspected community-acquired pneumonia. Results were made available in a reasonable interval, and negative ones were associated with a low antibiotic prescription rate.

Schlagwörter

community-acquired pneumoniaemergency departmentradiation dosediagnostic yieldantibiotic prescribingtime to resultfeasibilityhealthy adults

Zitieren

APA

Bianco, D., Acoorsi, T., Souza, J. D., Mello, E., Silva, J., Telles, Gustavo, Chate, R. C., Santos, A., Moron, R., Mattos, F., Telles, A., Oliveira, R., Almeida, E. D., Zimmer, P., Funari, Marcelo, Benveniste, Marcelo, …, & Gilberto (2023). Ultra-low Dose Computed Tomography for Pneumonia in the Emergency Department: A Feasibility Study. Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). https://doi.org/10.25748/arp.33024

Vancouver

Bianco D, Acoorsi T, Souza JD, Mello E, Silva J, Telles, et al. Ultra-low Dose Computed Tomography for Pneumonia in the Emergency Department: A Feasibility Study. Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). 2023. doi:10.25748/arp.33024

BibTeX
@article{Bianco2023,
  author = {Bianco, Danilo and Acoorsi, Tarso and Souza, José de and Mello, Eduardo and Silva, Joselito and Telles and Gustavo and Chate, Rodrigo Caruso and Santos, Andre and Moron, Renato and Mattos, Fernando and Telles, Adriana and Oliveira, Roger and Almeida, Elizabeth de and Zimmer, Paulo and Funari and Marcelo and Benveniste and Marcelo and Szarf and Gilberto},
  title = {Ultra-low Dose Computed Tomography for Pneumonia in the Emergency Department: A Feasibility Study},
  journal = {Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)},
  year = {2023},
  doi = {10.25748/arp.33024}
}
Kostenlos starten →