Quality by Design-Assisted Development and Validation of a Robust Analytical Method for Quantification of Vorasidenib and Its Process-Related Impurities
Research Journal of Chemistry and Environment · 31.12.2025 · 2 (30) · 81
DOI: 10.25303/302rjce081089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Research Journal of Chemistry and Environment, online erschienen am 31.12.2025. Verfasst von Rahul Gunupati und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
A robust and reliable HPLC method was developed and validated for the quantification of vorasidenib and its process-related impurities. The initial method development was performed with different stationary phases and mobile phase combinations. These trails demonstrate inadequate separation of analytes with poor resolution, co-elution and peak tailing. These limitations were overcome by adopting Box–Behnken experimental design in Quality by Design (QbD) approach. Three critical method parameters (CMPs) such as percentage of acetonitrile, mobile phase pH and flow rate were systematically optimized by considering critical quality attributes (CQAs) such as resolution between vorasidenib and impurity 4, resolution between impurities 1 and 4 and the tailing factor of impurity 4. The statistical analysis by ANOVA confirms the significance of all studied factors (p < 0.05), with mobile phase pH being the most influential factor for to the resolution of analytes. The optimized method comprises of Phenomenex Luna® C18 column (250 × 4.6 mm, 5 µm), acetate buffer at pH 3.0 and acetonitrile (40:60, v/v) at 0.8 mL/min and UV detection at 265 nm. The method linearity was observed within 10-60 µg/mL for vorasidenib and 0.1-0.6 µg/mL for impurities, with correlation coefficients (r²) higher than 0.999. The precision studies demonstrate %RSD values of below 2.0% across intra-day, inter-day and ruggedness analyses confirming the excellent repeatability and reproducibility of method. The accuracy was assessed through recovery studies and yields satisfying % recoveries in between 98% and 102%. The sensitivity studies confirm very low LODs (0.012–0.030 µg/mL) and LOQs (0.010–0.100 µg/mL) indicating the suitability of method for trace-level impurity quantification.
Zitieren
APA
Gunupati, R., Rao, T. B., Sailaja, O., Lakshmi, M., & Rambabu, D. (2025). Quality by Design-Assisted Development and Validation of a Robust Analytical Method for Quantification of Vorasidenib and Its Process-Related Impurities. Research Journal of Chemistry and Environment, 2(30), 81. https://doi.org/10.25303/302rjce081089
Vancouver
Gunupati R, Rao TB, Sailaja O, Lakshmi M, Rambabu D. Quality by Design-Assisted Development and Validation of a Robust Analytical Method for Quantification of Vorasidenib and Its Process-Related Impurities. Research Journal of Chemistry and Environment. 2025;2(30):81. doi:10.25303/302rjce081089
BibTeX
@article{Gunupati2025,
author = {Gunupati, Rahul and Rao, T. Bhaskara and Sailaja, Ommi and Lakshmi, M.V. and Rambabu, Dasari},
title = {Quality by Design-Assisted Development and Validation of a Robust Analytical Method for Quantification of Vorasidenib and Its Process-Related Impurities},
journal = {Research Journal of Chemistry and Environment},
year = {2025},
volume = {2},
number = {30},
pages = {81},
doi = {10.25303/302rjce081089}
}
EUVIMED