EUVIMEDEUVIMED entdecken
Crossref

Development and Validation of an Analytical Quality by Design‐Based Robust Liquid Chromatography Method for Determination of Eight Process and Degradation Impurities in Corticosteroid Drug Product

Sreenivasa Rao Battula, Siva Prasad Korikana, Naresh Konduru, Sree Hari Karini, Sai Kumar Badam, Kousrali Sayyad, Ramakrishna Chinthala

SEPARATION SCIENCE PLUS · 2026-11 · 9 (11)

DOI: 10.1002/sscp.70342 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SEPARATION SCIENCE PLUS, online erschienen am 01.11.2026. Verfasst von Sreenivasa Rao Battula und 6 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The current study focuses on the development and validation of a robust liquid chromatographic method for detecting process‐related and degradation impurities in prednisone tablet formulations, a drug commonly used to treat inflammatory and respiratory disorders. The chromatographic separation was achieved using an X‐Select HSS T3 column (250 mm × 4.6 mm, 5 µm) with a gradient elution system comprising potassium phosphate buffer (pH 2.0) and a mixture of acetonitrile, water, and tetrahydrofuran (50:35:15, v/v/v), delivered at a flow rate of 1.0 mL/min. Detection was done at 244 nm. The method was verified using ICH Q2(R2) guidelines and showed excellent linearity from the limit of quantification to 200% of the specification level ( R 2 > 0.9991). Recovery values ranged from 95.3% to 103.4%, confirming accuracy. Precision was within acceptable levels (relative standard deviation

Zitieren

APA

Battula, S. R., Korikana, S. P., Konduru, N., Karini, S. H., Badam, S. K., Sayyad, K., & Chinthala, R. (2026). Development and Validation of an Analytical Quality by Design‐Based Robust Liquid Chromatography Method for Determination of Eight Process and Degradation Impurities in Corticosteroid Drug Product. SEPARATION SCIENCE PLUS, 9(11). https://doi.org/10.1002/sscp.70342

Vancouver

Battula SR, Korikana SP, Konduru N, Karini SH, Badam SK, Sayyad K, et al. Development and Validation of an Analytical Quality by Design‐Based Robust Liquid Chromatography Method for Determination of Eight Process and Degradation Impurities in Corticosteroid Drug Product. SEPARATION SCIENCE PLUS. 2026;9(11). doi:10.1002/sscp.70342

BibTeX
@article{Battula2026,
  author = {Battula, Sreenivasa Rao and Korikana, Siva Prasad and Konduru, Naresh and Karini, Sree Hari and Badam, Sai Kumar and Sayyad, Kousrali and Chinthala, Ramakrishna},
  title = {Development and Validation of an Analytical Quality by Design‐Based Robust Liquid Chromatography Method for Determination of Eight Process and Degradation Impurities in Corticosteroid Drug Product},
  journal = {SEPARATION SCIENCE PLUS},
  year = {2026},
  volume = {9},
  number = {11},
  doi = {10.1002/sscp.70342}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche