Comparative evaluation of light microscopy, phase-contrast microscopy, and an automated analyzer in the detection of dysmorphic red blood cells in hematuria
Journal of Laboratory Physicians · 12.06.2026 · 18 · 133-139
DOI: 10.25259/jlp_370_2025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Laboratory Physicians, online erschienen am 12.06.2026. Verfasst von Prerna Prasad und 5 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
Objectives
Urinalysis remains a fundamental diagnostic tool in the evaluation of renal and urological disorders. Differentiation between glomerular and non-glomerular hematuria based on red blood cell (RBC) morphology is critical for clinical decision-making. While phase-contrast microscopy (PCM) is considered the reference standard for identifying dysmorphic RBCs (dRBCs), its limited availability and operator dependency necessitate assessment of alternative methods. This study aimed to compare light microscopy (LM), PCM, and the DIRUI FUS-1000 automated urine analyzer for detecting dRBCs and identifying glomerular hematuria. Materials and Methods: This cross-sectional study included 150 patients presenting with hematuria. Fresh urine samples from each patient were examined independently using LM, PCM, and the DIRUI FUS-1000 automated urine analyzer. The origin of hematuria (glomerular or non-glomerular) was determined using a composite reference standard incorporating clinical findings, laboratory investigations, imaging studies, and histopathological data where available. Statistical analysis: Diagnostic performance parameters, including sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy, were calculated for each modality. Receiver operating characteristic (ROC) curve analysis was performed to assess diagnostic discrimination and determine optimal cut-off values for dRBC percentages. Statistical analysis was conducted using the Statistical Package for the Social Sciences version 22.0.
Results
Of the 150 cases analyzed, 102 (68%) were classified as having glomerular hematuria and 48 (32%) as non-glomerular hematuria. PCM demonstrated the highest diagnostic accuracy, with a sensitivity of 100%, specificity of 75%, and an area under the ROC curve (AUC) of 0.97 at a cut-off value of 21% dRBCs. LM showed moderate diagnostic performance (sensitivity 77.4%, specificity 56.3%, and AUC 0.76). The automated urine analyzer demonstrated comparable sensitivity to LM but lower specificity, with an AUC of 0.72.
Conclusions
PCM remains the reference standard for identifying dRBCs and diagnosing glomerular hematuria. However, LM and automated urine analyzers serve as practical screening tools, particularly in high-volume laboratory settings. Emerging artificial intelligence-assisted digital urine microscopy platforms hold promise for improving reproducibility, diagnostic accuracy, and workflow efficiency in routine urinalysis.
Zitieren
APA
Prasad, P., Kala, M., Ahmad, S., Dhebane, M., Saklani, B., & Chandra, S. (2026). Comparative evaluation of light microscopy, phase-contrast microscopy, and an automated analyzer in the detection of dysmorphic red blood cells in hematuria. Journal of Laboratory Physicians, 18, 133-139. https://doi.org/10.25259/jlp_370_2025
Vancouver
Prasad P, Kala M, Ahmad S, Dhebane M, Saklani B, Chandra S. Comparative evaluation of light microscopy, phase-contrast microscopy, and an automated analyzer in the detection of dysmorphic red blood cells in hematuria. Journal of Laboratory Physicians. 2026;18:133-139. doi:10.25259/jlp_370_2025
BibTeX
@article{Prasad2026,
author = {Prasad, Prerna and Kala, Mansi and Ahmad, Shahbaj and Dhebane, Meghali and Saklani, Bharti and Chandra, Smita},
title = {Comparative evaluation of light microscopy, phase-contrast microscopy, and an automated analyzer in the detection of dysmorphic red blood cells in hematuria},
journal = {Journal of Laboratory Physicians},
year = {2026},
volume = {18},
pages = {133--139},
doi = {10.25259/jlp_370_2025}
}
EUVIMED