EUVIMEDEUVIMED entdecken
Crossref

Impact of resin composite type on enamel surface damage during rotary instrument removal in aligner therapy: An in vitro study

Ludovica Nucci, Vito Agostinacchio, Federico Sassatelli, Andrea Scribante, Cristina Grippaudo, Nikhilesh Vaid

APOS Trends in Orthodontics · 07.03.2026 · 16 · 201-207

DOI: 10.25259/apos_138_2025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift APOS Trends in Orthodontics, online erschienen am 07.03.2026. Verfasst von Ludovica Nucci und 5 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Attachments are composite structures that help clear aligners (CAs) move teeth and must be removed at the end of treatment. Made from various composites, they are sometimes replaced during therapy. This study evaluates enamel damage after removing attachments made from three different composites, aiming to determine whether the type of resin affects the extent of damage caused by rotary instruments. Material and Methods: This in vitro study used 30 extracted teeth, divided into three groups: A (packable composite), B (flowable composite), and C (orthodontic composite). Before bonding (T0), each tooth was duplicated in epoxy resin. Attachments were applied using a consistent protocol, then removed with a tungsten carbide bur. After removal (T1), teeth were finished with sandpaper discs and polished with pumice paste. Impressions were taken to create resin replicas. Enamel damage was assessed using scanning electron microscopy (SEM), and a modified enamel damage index (EDI) was applied. Data were analyzed with a Chi-square test ( p < 0.05).

Results

Groups A (packable composite) and C (orthodontic composite) showed a significant difference in enamel damage ( p = 0.0235) at T1. However, there were no significant differences between Group B (flowable composite) and the other groups ( p > 0.05).

Conclusion

Attachment removal causes enamel damage, with greater damage observed in the packable composite group compared to the orthodontic composite group. Group A (packable composite) shows a heterogeneous distribution, with a prevalence of EDI 2 (60%) and lower proportions of EDI 1 and EDI 3 (20% each). In Group B (flowable composite), EDI 1 predominates (60%), followed by EDI 2 (40%). Finally, Group C (orthodontic composite) is characterized almost exclusively by EDI 1 values (80%), with a residual proportion of EDI 2 (20%). These results suggest that the type of composite used for attachments influences enamel surface integrity during removal.

Zitieren

APA

Nucci, L., Agostinacchio, V., Sassatelli, F., Scribante, A., Grippaudo, C., & Vaid, N. (2026). Impact of resin composite type on enamel surface damage during rotary instrument removal in aligner therapy: An in vitro study. APOS Trends in Orthodontics, 16, 201-207. https://doi.org/10.25259/apos_138_2025

Vancouver

Nucci L, Agostinacchio V, Sassatelli F, Scribante A, Grippaudo C, Vaid N. Impact of resin composite type on enamel surface damage during rotary instrument removal in aligner therapy: An in vitro study. APOS Trends in Orthodontics. 2026;16:201-207. doi:10.25259/apos_138_2025

BibTeX
@article{Nucci2026,
  author = {Nucci, Ludovica and Agostinacchio, Vito and Sassatelli, Federico and Scribante, Andrea and Grippaudo, Cristina and Vaid, Nikhilesh},
  title = {Impact of resin composite type on enamel surface damage during rotary instrument removal in aligner therapy: An in vitro study},
  journal = {APOS Trends in Orthodontics},
  year = {2026},
  volume = {16},
  pages = {201--207},
  doi = {10.25259/apos_138_2025}
}
Kostenlos starten →