EUVIMEDEUVIMED entdecken
Open Access

Effects of refinement procedures on enamel surface integrity in clear aligner therapy: a 3D micro-CT study

Hilal Turkoglu-Boynuyogun, Irmak Ocak, Ezgi Atik

The Angle Orthodontist · 01.04.2026

DOI: 10.2319/102225-871.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Angle Orthodontist, erschienen am 01.04.2026. Verfasst von Hilal Turkoglu-Boynuyogun und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: X-Ray Microtomography, Dental Enamel, Dental Debonding. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate topographic changes on the enamel surface after different debonding methods of clear aligner attachments using three-dimensional (3D) micro-computed tomography (Micro-CT). Materials and Methods Vertical rectangular attachments were attached to 20 premolars and divided into two subgroups (N = 10) using different debonding methods. Micro-CT scans were performed showing the enamel surfaces of each group before bonding (T0), after the first debonding procedure (T1), and after the second debonding with polishing (T2). In Group 1, excess attachment composite was removed with a 12-blade carbide bur, followed by a 24-blade carbide bur, and then the tooth surface was polished with a Renew stone. In Group 2, the attachment composite was removed with a Komet-H23VIP bur and polished with a compatible polishing kit. Morphological changes in the enamel surface were compared within groups using repeated-measures analysis of variance and between groups using independent samples t -tests. Values of P < .05 were considered statistically significant.

Results

Significant decreases in enamel demineralization volume ( P < .001), area (Group 1: P < .001; Group 2: P = .020), and mineral density ( P < .001) were observed in both groups. Intragroup comparison revealed no significant difference in demineralization volume or area changes, but enamel mineral density was better preserved in Group 2 (T1-T2, P = .006; T0-T2, P = .008).

Conclusions

The cumulative effect of repeated attachment debonding is significant, with tissue loss becoming more pronounced after the second application. The need for refinement should be carefully evaluated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

X-Ray MicrotomographyDental EnamelDental DebondingHumansImaging, Three-DimensionalSurface PropertiesBicuspid

Stichwörter der Autor:innen

Clear aligner attachmentDebondingMicro-CTOrthodonticsRefinement

Zitieren

APA

Turkoglu-Boynuyogun, H., Ocak, I., & Atik, E. (2026). Effects of refinement procedures on enamel surface integrity in clear aligner therapy: a 3D micro-CT study. The Angle Orthodontist. https://doi.org/10.2319/102225-871.1

Vancouver

Turkoglu-Boynuyogun H, Ocak I, Atik E. Effects of refinement procedures on enamel surface integrity in clear aligner therapy: a 3D micro-CT study. The Angle Orthodontist. 2026. doi:10.2319/102225-871.1

BibTeX
@article{TurkogluBoynuyogun2026,
  author = {Turkoglu-Boynuyogun, Hilal and Ocak, Irmak and Atik, Ezgi},
  title = {Effects of refinement procedures on enamel surface integrity in clear aligner therapy: a 3D micro-CT study},
  journal = {The Angle Orthodontist},
  year = {2026},
  doi = {10.2319/102225-871.1}
}
Kostenlos starten →