EUVIMEDEUVIMED entdecken
Crossref

Critical Analysis of Spectral Characteristics of FBG Sensor for Precise Monitoring in Medical Sensing Applications

Santosh Jotiram Jagatap, Dr. Ashok Jetawat, Dr. Saurabh Mehta, Dr. Jayshree Jetawat

International Journal of Drug Delivery Technology · 23.04.2026 · 16 (17s)

DOI: 10.25258/ijddt.16.17s.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 23.04.2026. Verfasst von Santosh Jotiram Jagatap und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fiber Bragg Grating sensors are most promising to fulfill needs of transformed healthcare standards. Optical fiber sensors use optical detection principle rather than electronic principle used in conventional electronic sensors. This not only offers advantage of small size and light weight but also offers high measurement sensitivity in noisy environment. FBGs offers high sensitivity compared to conventional electronic sensors as optical signal is isolated from noise and electromagnetic interference. The study of the structural parameters and spectral properties of fiber Bragg grating is equally important in medical sensing applications. The structural design of fiber Bragg grating sensor consist of grating which is formed by introducing periodic variation of refractive index of core. Grating reflects specific wavelength known as Bragg wavelength. The external stimulus such as temperature, strain and pressure introduces shift in the reflected Bragg wavelength. The strength of reflected Bragg wavelength known as reflectivity depends on its structural parameters such as grating length, period and modulation index. The spectral response of fiber Bragg grating sensors shows some undesired reflected wavelengths along with desired Bragg wavelength. These undesired wavelengths are known as side lobe levels and contributes noise affecting detection sensitivity. Hence high reflectivity and low side lobe levels are essential for high sensitivity and precise measurement of medical parameters. In this research work, the effect of structural parameters on spectral response is demonstrated by developing mathematical and simulation model. The sensor design is optimised for high reflectivity and minimum side lobe levels. The apodization techniques are introduced and comparative analysis is done to get desired level of reflectivity and side lobe levels. The proposed fiber Bragg grating sensor model is suitable for precise monitoring of healthcare parameters in medical sensing applications.

Zitieren

APA

Jagatap, S. J., Jetawat, D. A., Mehta, D. S., & Jetawat, D. J. (2026). Critical Analysis of Spectral Characteristics of FBG Sensor for Precise Monitoring in Medical Sensing Applications. International Journal of Drug Delivery Technology, 16(17s). https://doi.org/10.25258/ijddt.16.17s.1

Vancouver

Jagatap SJ, Jetawat DA, Mehta DS, Jetawat DJ. Critical Analysis of Spectral Characteristics of FBG Sensor for Precise Monitoring in Medical Sensing Applications. International Journal of Drug Delivery Technology. 2026;16(17s). doi:10.25258/ijddt.16.17s.1

BibTeX
@article{Jagatap2026,
  author = {Jagatap, Santosh Jotiram and Jetawat, Dr. Ashok and Mehta, Dr. Saurabh and Jetawat, Dr. Jayshree},
  title = {Critical Analysis of Spectral Characteristics of FBG Sensor for Precise Monitoring in Medical Sensing Applications},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {17s},
  doi = {10.25258/ijddt.16.17s.1}
}
Kostenlos starten →