EUVIMEDEUVIMED entdecken
Crossref

Airway Complications during Laparoscopic Surgery Under General Anesthesia Using Endotracheal Tube Versus Supraglottic Airway Device: A Prospective Comparative Study

Madhavi Siddharth Mavani, Krupalibahen Rangadiya, Urvi Tushar Shah

International Journal of Current Pharmaceutical Review and Research · 30.06.2026 · 18 (06)

DOI: 10.25258/ijcpr.18.6.43 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 30.06.2026. Verfasst von Madhavi Siddharth Mavani und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pneumoperitoneum during laparoscopic surgery under general anesthesia is known to cause a decrease in pulmonary compliance and increase in airway pressures. Traditionally, endotracheal tubes (ETTs) have been used because they create a definitive airway, while second generation supraglottic airway devices (SGAs) have been shown to seal the airway better and to drain the stomach with less stimulation of the airway. The aim of the present study was to compare the incidence of airway complications in ETT and SGA in elective laparoscopy.

Methods

This was a prospective comparative study of 120 adult ASA physical status I-II patients undergoing elective laparoscopic surgery. Patients were randomized to either ETT (n=60) or SGA (n=60; second generation device with gastric drainage channel). The following were used: standardized induction, neuromuscular blockade, controlled ventilation, pneumoperitoneum pressure, and postoperative assessment. The main outcome was the composite of airway complications within 24 hours. Secondary outcomes were device insertion characteristics, ventilatory variables, hemodynamic responses, postoperative sore throat, cough, and hoarseness, nausea-vomiting, and PACU discharge time.

Results

There were no differences in baseline characteristics between groups. The mean insertion time was significantly less for SGA than ETT (15.2±3.8 vs. 22.8±5.4 seconds; p

Zitieren

APA

Mavani, M. S., Rangadiya, K., & Shah, U. T. (2026). Airway Complications during Laparoscopic Surgery Under General Anesthesia Using Endotracheal Tube Versus Supraglottic Airway Device: A Prospective Comparative Study. International Journal of Current Pharmaceutical Review and Research, 18(06). https://doi.org/10.25258/ijcpr.18.6.43

Vancouver

Mavani MS, Rangadiya K, Shah UT. Airway Complications during Laparoscopic Surgery Under General Anesthesia Using Endotracheal Tube Versus Supraglottic Airway Device: A Prospective Comparative Study. International Journal of Current Pharmaceutical Review and Research. 2026;18(06). doi:10.25258/ijcpr.18.6.43

BibTeX
@article{Mavani2026,
  author = {Mavani, Madhavi Siddharth and Rangadiya, Krupalibahen and Shah, Urvi Tushar},
  title = {Airway Complications during Laparoscopic Surgery Under General Anesthesia Using Endotracheal Tube Versus Supraglottic Airway Device: A Prospective Comparative Study},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {06},
  doi = {10.25258/ijcpr.18.6.43}
}
Kostenlos starten →