Rapid Airway Placement Without Pausing Chest Compressions: Supraglottic Airway Versus Endotracheal Intubation
Pediatrics International · 2026-01 · 68 (1)
DOI: 10.1111/ped.70496 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Pediatrics International, online erschienen am 21.07.2026. Verfasst von Masaki Tatsumi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Kitano Hospital, Tazuke Kofukai Medical Research Institute, Osaka, Japan. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Cardiopulmonary Resuscitation, Heart Massage. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Aim
To compare supraglottic airway device (i‐gel) placement versus endotracheal intubation during neonatal cardiopulmonary resuscitation (CPR) and to assess whether ongoing chest compressions affect success or procedure time in a manikin simulation.
Methods
We conducted a randomized crossover neonatal resuscitation simulation for pediatric and junior residents at a single tertiary hospital. A term 3‐kg infant scenario required positive‐pressure ventilation and chest compressions. Participants performed 15 cycles of CPR, placed an advanced airway, and then continued CPR for 15 cycles. Each participant completed four conditions: endotracheal intubation with and without chest‐compression interruption, and i‐gel placement with and without interruption. Outcomes were success rate and procedure time (from device pickup to ventilation).
Results
Twelve residents participated. Endotracheal intubation success rates were 92% (11/12) without interruption and 83% (10/12) with interruption; median procedure times were 16.5 s (range 13–84) and 16 s (11–24), respectively. i‐gel placement succeeded in 100% (12/12) in both conditions and was faster: median 7.5 s (6–11) without interruption and 7 s (6–10) with interruption. In paired comparisons, i‐gel was significantly faster than intubation in both conditions (paired Wilcoxon p < 0.01), whereas success rates did not differ significantly (McNemar exact p > = 0.50).
Conclusions
In this neonatal manikin simulation, i‐gel placement enabled earlier initiation of ventilation than endotracheal intubation and remained consistently successful and rapid even during ongoing chest compressions. Chest‐compression interruption did not significantly change intubation success or time in this small sample.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatrics, Kitano Hospital, Tazuke Kofukai Medical Research Institute, Osaka, Japan.
ORCID-Profile: Risa Asui, Hiroshi Mizumoto
Zitieren
APA
Tatsumi, M., Asui, R., & Mizumoto, H. (2026). Rapid Airway Placement Without Pausing Chest Compressions: Supraglottic Airway Versus Endotracheal Intubation. Pediatrics International, 68(1). https://doi.org/10.1111/ped.70496
Vancouver
Tatsumi M, Asui R, Mizumoto H. Rapid Airway Placement Without Pausing Chest Compressions: Supraglottic Airway Versus Endotracheal Intubation. Pediatrics International. 2026;68(1). doi:10.1111/ped.70496
BibTeX
@article{Tatsumi2026,
author = {Tatsumi, Masaki and Asui, Risa and Mizumoto, Hiroshi},
title = {Rapid Airway Placement Without Pausing Chest Compressions: Supraglottic Airway Versus Endotracheal Intubation},
journal = {Pediatrics International},
year = {2026},
volume = {68},
number = {1},
doi = {10.1111/ped.70496}
}