EUVIMEDEUVIMED entdecken
Crossref

Assessment of Tip–Apex Distance as a Predictor of Implant Failure in Intertrochanteric Femur Fractures: A Prospective Observational Study

Intekhab Akram, Umesh Prasad, Marut Nandan Kumar, Rakesh Chaudhary

International Journal of Current Pharmaceutical Review and Research · 30.06.2026 · 18 (06)

DOI: 10.25258/ijcpr.18.6.196 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 30.06.2026. Verfasst von Intekhab Akram und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The intertrochanteric femur fracture is one of the most prevalent orthopedic injuries in the elderly and has a significant morbidity and health care utilization. A failure of the implant after surgical fixation is still a major concern, and Tip-Apex Distance (TAD) has been suggested as an important predictor of the success of surgical fixation.

Methods

A prospective observational study was carried out in the Department of Orthopaedics, Patna Medical College and Hospital (PMCH), Patna, Bihar, from April 2025 to December 2025. The total number of 50 patients with intertrochanteric femur fracture treated with Dynamic Hip Screw (DHS) or Proximal Femoral Nail (PFN). The postoperative TAD was assessed by the anteroposterior and lateral radiographs. The patients had a 6-month follow-up to evaluate implant-related outcomes. Data were analyzed statistically by SPSS version 26.0, and p < 0.05, the results were regarded as significant.

Results

Of the 50 patients, 36 (72%) had a TAD ≤25 mm and 14 (28%) had a TAD >25 mm. Implant failure occurred in 8 patients (16%). The failure rate in patients with TAD >25 mm was significantly higher than in patients with TAD ≤25 mm (42.9% vs. 5.6%, p = 0.003).

Conclusion

The length of the tip to the apex of the femur fracture is an important predictor of implant failure in intertrochanteric femur fractures. A TAD measuring 25 mm or less could reduce the risk of fixation failure and improve surgical outcomes.

Zitieren

APA

Akram, I., Prasad, U., Kumar, M. N., & Chaudhary, R. (2026). Assessment of Tip–Apex Distance as a Predictor of Implant Failure in Intertrochanteric Femur Fractures: A Prospective Observational Study. International Journal of Current Pharmaceutical Review and Research, 18(06). https://doi.org/10.25258/ijcpr.18.6.196

Vancouver

Akram I, Prasad U, Kumar MN, Chaudhary R. Assessment of Tip–Apex Distance as a Predictor of Implant Failure in Intertrochanteric Femur Fractures: A Prospective Observational Study. International Journal of Current Pharmaceutical Review and Research. 2026;18(06). doi:10.25258/ijcpr.18.6.196

BibTeX
@article{Akram2026,
  author = {Akram, Intekhab and Prasad, Umesh and Kumar, Marut Nandan and Chaudhary, Rakesh},
  title = {Assessment of Tip–Apex Distance as a Predictor of Implant Failure in Intertrochanteric Femur Fractures: A Prospective Observational Study},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {06},
  doi = {10.25258/ijcpr.18.6.196}
}
Kostenlos starten →