Biomechanical Analysis of Different Bearing Surfaces in Total Hip Arthroplasty: A Finite Element Study
International Journal of Current Pharmaceutical Review and Research · 31.05.2026 · 18 (05)
DOI: 10.25258/ijcpr.18.5.266 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 31.05.2026. Verfasst von Sikandar Rajak und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Total hip arthroplasty (THA) survivorship is strongly influenced by the tribological behavior of the bearing couple. Although contemporary ceramic and highly cross-linked polyethylene bearings have improved long-term outcomes, comparative biomechanical data on contact pressure, stress transfer, and predicted wear across commonly used bearing surfaces remain important for implant selection and preoperative planning.
Aim
To compare the biomechanical performance of ceramic-on-ceramic, ceramic-on-highly cross-linked polyethylene, ceramic-on-polyethylene, and metal-on-polyethylene bearings using a patient-linked finite element framework.
Methods
This study was done around 80 patient-specific primary THA cases from Jawahar Lal Nehru Medical College & Hospital, Bhagalpur, Bihar, India, for the study period January 2024 to December 2025. Eighty reconstructed hip models were implanted with identical component geometry and sequentially simulated with four bearing surfaces, generating 320 finite element simulations. Peak contact pressure, peak von Mises stress, contact area, peak frictional shear stress, and estimated volumetric wear rate were extracted under standardized gait loading. Repeated-measures ANOVA and patient-clustered generalized estimating equation models were used for analysis.
Results
Bearing surface significantly affected all biomechanical endpoints (all p
Zitieren
APA
Rajak, S., Ranjan, P., Lal, M., & Raj, S. (2026). Biomechanical Analysis of Different Bearing Surfaces in Total Hip Arthroplasty: A Finite Element Study. International Journal of Current Pharmaceutical Review and Research, 18(05). https://doi.org/10.25258/ijcpr.18.5.266
Vancouver
Rajak S, Ranjan P, Lal M, Raj S. Biomechanical Analysis of Different Bearing Surfaces in Total Hip Arthroplasty: A Finite Element Study. International Journal of Current Pharmaceutical Review and Research. 2026;18(05). doi:10.25258/ijcpr.18.5.266
BibTeX
@article{Rajak2026,
author = {Rajak, Sikandar and Ranjan, Parbhat and Lal, Makhan and Raj, Shubham},
title = {Biomechanical Analysis of Different Bearing Surfaces in Total Hip Arthroplasty: A Finite Element Study},
journal = {International Journal of Current Pharmaceutical Review and Research},
year = {2026},
volume = {18},
number = {05},
doi = {10.25258/ijcpr.18.5.266}
}
EUVIMED