Effect of Time and Storage Condition on Prothrombin Time and Activated Partial Thromboplastin Time
International Journal of Current Pharmaceutical Review and Research · 30.04.2026 · 18 (04)
DOI: 10.25258/ijcpr.18.4.92 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 30.04.2026. Verfasst von Karthikeyan T. M. und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Prothrombin Time (PT) and Activated Partial Thromboplastin Time (aPTT) are vital coagulation tests done to evaluate the extrinsic and intrinsic pathways, respectively. Pre-analytical variables such as delay in time to process and storage conditions can significantly affect the test results, influencing the clinical decisionmaking.
Objective
To assess the effect of time and storage conditions (room temperature and refrigeration) on PT and aPTT values in blood samples. Materials and Methods: This prospective cross-sectional study was conducted on 30 healthy volunteers between the age group of 18–25 years. Blood samples were collected in 3.2% sodium citrate tubes. Two sets of samples were processed: one set of samples are centrifuged immediately and the obtained plasma is stored in refrigerator, and another set of samples are kept as whole blood at room temperature. PT and aPTT were measured at the time interval of 0, 4, 12, and 24 hours using a fully automated coagulation analyzer (Elite Pro ACL). Statistical analysis was performed using repeated measures ANOVA.
Results
PT showed no difference in values between centrifuged and uncentrifuged samples significantly but there was a gradual decline over time but remained relatively stable upto 24 hours. In contrast, aPTT values showed a significant decrease over time, specifically after 4 hours, in both centrifuged and uncentrifuged samples. Statistically significant differences were observed at the interval of 12 and 24 hours (p < 0.05).
Conclusion
PT is stable up to 24 hours under both room temperature and refrigerated conditions. However, aPTT is time-sensitive and should ideally be processed within 4 hours for accuracy. If there is a delay for analysing the sample, separation of plasma and refrigeration are recommended to retain the sample integrity.
Zitieren
APA
M., K. T., R., S., S., U. M., K., S., & Fedric, P. (2026). Effect of Time and Storage Condition on Prothrombin Time and Activated Partial Thromboplastin Time. International Journal of Current Pharmaceutical Review and Research, 18(04). https://doi.org/10.25258/ijcpr.18.4.92
Vancouver
M. KT, R. S, S. UM, K. S, Fedric P. Effect of Time and Storage Condition on Prothrombin Time and Activated Partial Thromboplastin Time. International Journal of Current Pharmaceutical Review and Research. 2026;18(04). doi:10.25258/ijcpr.18.4.92
BibTeX
@article{M2026,
author = {M., Karthikeyan T. and R., Shivapriya and S., Umamageswari M. and K., Sharanya and Fedric, Priya},
title = {Effect of Time and Storage Condition on Prothrombin Time and Activated Partial Thromboplastin Time},
journal = {International Journal of Current Pharmaceutical Review and Research},
year = {2026},
volume = {18},
number = {04},
doi = {10.25258/ijcpr.18.4.92}
}
EUVIMED