Interpretation of Prothrombin Time and Activated Partial Thromboplastin Time Mixing Studies Using Predefined Algorithms
Clinical and Applied Thrombosis/Hemostasis · 2026-01 · 32
DOI: 10.1177/10760296261464807 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Applied Thrombosis/Hemostasis, online erschienen am 25.06.2026. Verfasst von Fatima Farhan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology & Laboratory Medicine, Aga Khan University, Karachi, Pakistan. Hauptthemen laut MEDLINE: Prothrombin Time, Algorithms. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Mixing test plasma with prolonged Prothrombin Time (PT) and activated partial thromboplastin time (aPTT) with normal plasma in a 1:1 ratio, helps distinguish between clotting factor deficiency and inhibitors. In our clinical laboratory, the upper reference interval (URI) is routinely used to determine correction (or no correction) in mixing studies. Aims and objectives We aimed to use the International Council for Standardization in Haematology. (ICSH) 2024 recommendations for interpreting PT/aPTT mixing studies following validation of the defined cutoffs. Materials and Methods From December 2022 to December 2024, plasma samples with prolonged PT/aPTT were tested by mixing them with normal pooled plasma at a 1:1 ratio. A cut-off of ≥70% correction or ≤15% Rosner Index was used to identify clotting factor deficiency per ICSH, and this was compared with URI.
Results
After validating the cutoffs, the analysis of mixing results and factor assays was performed on 243 patients with prolonged PT (n=54), aPTT (n=56), and PT/aPTT (n=133). All patients exhibited either single or multiple clotting factor deficiencies. Inhibitor detection varied depending on the interpretive criteria: the upper reference interval method identified 12/243 cases (4.9%), the 70% correction criterion identified 20/243 cases (8.2%) overall, and the Rosner Index identified 7/189 cases (3.7%) among samples with prolonged aPTT, highlighting method-dependent discordance. Agreement between the various methods was 90.0% or higher.
Conclusion
The ICSH recommendations accurately identified clotting factor deficiencies after local validation of the cut-offs. Clinical correlation and appropriate laboratory testing are essential for detecting concurrent inhibitors in clotting factor deficiency.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pathology & Laboratory Medicine, Aga Khan University, Karachi, Pakistan.
ORCID-Profile: Bushra Moiz
Zitieren
APA
Farhan, F., Rizvi, B. A., & Moiz, B. (2026). Interpretation of Prothrombin Time and Activated Partial Thromboplastin Time Mixing Studies Using Predefined Algorithms. Clinical and Applied Thrombosis/Hemostasis, 32. https://doi.org/10.1177/10760296261464807
Vancouver
Farhan F, Rizvi BA, Moiz B. Interpretation of Prothrombin Time and Activated Partial Thromboplastin Time Mixing Studies Using Predefined Algorithms. Clinical and Applied Thrombosis/Hemostasis. 2026;32. doi:10.1177/10760296261464807
BibTeX
@article{Farhan2026,
author = {Farhan, Fatima and Rizvi, Bushra Afaq and Moiz, Bushra},
title = {Interpretation of Prothrombin Time and Activated Partial Thromboplastin Time Mixing Studies Using Predefined Algorithms},
journal = {Clinical and Applied Thrombosis/Hemostasis},
year = {2026},
volume = {32},
doi = {10.1177/10760296261464807}
}
EUVIMED